Applies to CAMAC systems as defined in IEC 60516. The generic standard for BASIC includes a real-time enhancement which is necessarily general. This standard defines specific syntax and semantics for use with CAMAC.
Digital counting ratemeters - Characteristics and test methods
Applies to digital ratemeters used in nuclear instrumentation to measure periodic or random pulse counting rates as produced by detectors. Defines the characteristics used for expressing functional performance and establishes the test methods recommended for measuring and verifying such characteristics.
Formsets for Use with Embossed Cards and Imprinting Equipment
1. Scope
1.1 The purpose of this Standard is to define common media for the transferring of information from sources, including the embossed characters on a card, by means of imprinting equipment.
1.2 The existence of two standards in relation to formset dimensions is recognized as are the several different methods of capturing the information contained on completed formsets.
1.3…
Requirements for the Reactor Regulating Systems of CANDU Nuclear Power Plants
1. Scope
1.1 The Standard is concerned with two aspects of the reactor regulating system. The first relates to reactor safety; the second is concerned with effective control of the reactor. These two aspects are not separate. This Standard, therefore, addresses itself to two points:
(a) To ensure that the reactor regulating system operates to limit, to acceptable values, the frequency…
Design Requirements for Concrete Containment Structures for CANDU Nuclear
Power Plants
This Standard provides the requirements for the design of concrete containment
structures of a containment system, designated as "class containment"
components and parts, as defined in CSA Standard CAN3-N287.1, General
Requirements for Concrete Containment Structures for CANDU Nuclear Power
Plants.
Pneumatic fluid power systems — Cylinder barrels — Requirements for non-ferrous metallic tubes
Covers non-ferrous metallic pneumatic cylinder tubes. Defines the mechanical properties, dimensional tolerances, surface finishes, and technical delivery conditions of the following tubes and bores for pneumatic fluid power cylinders: round non-ferrous metallic tubes, seamless or welded type, in the as-drawn stress-relieved or fully heat-treated condition; bores, specially finished, with or…
Photography — Cameras — Automatic controls of exposure
ISO 2721:1982 defines the exposure at the focal plane of cameras for values of two exposure parameters, i.e. field luminance and film speed. It also gives methods of evaluating other photometric characteristics. The data apply to automatic exposure control systems which are built into cameras or coupled with them to regulate the exposure in the focal plane in dependence of the various exposure…
Sealing Compound, One Component, Elastomeric, Chemical Curing
Applies to one-component joint sealing compounds that cure to a
rubber-like solid and are suitable for sealing, caulking or
glazing applications. A sealing compound meeting the requirements
of this standard is designated by the manufacturer to be one or
more of the types, classes, grades, and uses defined in Section 3
of this standard. For application on a particular substrate the
primer,…
Acceptance conditions for boring and milling machines with horizontal spindle — Testing of the accur...
This part defines the machining operations that can be carried out an these machine tools. Describes the different types of machines: planer type machines, and movable column machines or floor type machines. Gives the terminology for the main elements of the machine (in English, French and Russian as well as equivalent terms in German and Italian.)
Black pepper and white pepper, whole or ground — Determination of piperine content — Spectrophotomet...
Describes a method based on a number of international collaborative studies carried out over a long period of time. The method seeks to optimize a number of variables in an attempt to define procedures and provide a common measure of the pungency of pepper. The principle consists in the extraction of the pungent compounds with ethanol and spectrophotometric measurement at 343 nm.