Scope
This National Standard of Canada applies to two types of petroleum distillates intended for use in applications as
described below.
b)
used in well-ventilated surroundings, and in wick-fed illuminating lamps.
a) Type No. 1-K Kerosene is intended for use in unvented space heaters as described in CSA B140.9.3, when
Type No. 2-K Kerosene is intended for use in flue-connected stoves and…
Scope
1.1 These requirements apply to factory-built gas-fired package boilers having input ratings of more than
400,000 Btu/h (117,228 W), per individual combustion chamber, having the following:
a) For the United States: Inlet/supply pressures up to 15 psi (103 kPa), and intended primarily for
commercial and industrial installation;
b) For Canada: Inlet/supply gas pressures ?0.5 psi (3.4…
1 Scope
1.1 Installation requirements for large oil-burning equipment
This Code specifies minimum requirements for the installation of large oil-burning equipment.
Note: The intent of this Code is to apply to multi-unit residential, commercial, institutional, and industrial buildings in accordance with the provincial building code or, in the absence of such regulation, the National Building…
Household and similar electrical appliances — Safety — Part 2-41: Particular requirements for pumps ...
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric pumps for liquids having a
temperature not exceeding 90 °C, intended for household and similar purposes, their rated
voltage being not more than 250 V for single-phase appliances and 480 V for other
appliances.
NOTE 101
This Standard covers both permanently…
Vapour control systems in gasoline distribution networks
Scope
This National Standard of Canada defines equipment requirements, performance criteria, and operating and testing
procedures for the implementation of a vapour control system (VCS) in gasoline distribution networks including
terminals, bulk plants, service stations and cargo tanks, commonly known as Stage I controls (see Figure 1 for a
schematic representation).
This standard does not…
Containment Sumps, Fittings and Accessories for Flammable and Combustible Liquids
Scope
1.1 This Standard sets forth the minimum requirements for containment sumps, and associated sump
fittings and accessories (products) intended for below-grade, or at-grade, or above-grade use as an
enclosure for the housing of, and access to, underground piping, connector piping, and other fueling
system components (such as pumps, valves, sensors, wiring, etc.), in addition to temporary…
Scope
1.1 These requirements apply to ultraviolet germicidal irradiation (UVGI) equipment and systems
intended for installation and use in accordance with the U.S. National Electrical Code (NEC), NFPA 70 and
in accordance with the Canadian Electrical Code, Part I (CEC), CSA C22.1. These requirements cover:
a) UV Germicidal Equipment – These devices emit uncontained UV energy into the…
Flexible Connector Piping for Flammable and Combustible Liquids
Scope
1.1 This Standard sets forth the minimum requirements for cover primary, secondary, and coaxial types
of flexible connector pipes intended for short length transfer and containment of the specific flammable
and combustible liquids (or vapors thereof) identified in this Standard, at commercial (public) or fleet
(private) automotive motor vehicle fueling stations or similar fuel…
Tuyaux de raccordement flexibles pour liquides inflammables et combustibles
Domaine d’application
1.1 La présente norme fournit les exigences minimums pour les types principaux, secondaires et
coaxiaux de tuyaux de raccordement flexibles destinés au transfert et à la rétention sur de courtes
distances de liquides (ou vapeurs) inflammables et combustibles spécifiques, comme décrit dans la
présente norme, dans les postes de ravitaillement commerciaux (publics) ou de…
1 Scope
1.1 Inclusions
This Standard applies to newly produced automatic valves constructed entirely of new, unused parts and materials. These valves can be individual automatic valves or valves utilized as parts of automatic gas ignition systems.
This Standard also applies to commercial/industrial safety shutoff valves herein after referred to as C/I valves.
Components performing functions…