Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids
Scope
1.1 This Standard sets forth minimum requirements for steel, non-pressure tanks that are used for the
aboveground storage of flammable and combustible liquids compatible with the material of construction
and with a specific gravity not greater than 1.0. Tanks storing liquids with a specific gravity greater than 1.0
are covered in 8.7. Tanks designed for higher static pressures are…
Norme sur les réservoirs hors sol en acier fabriqués en usine pour liquides inflammables et combusti...
Domaine d’application
1.1 La présente norme établit les exigences minimales applicables aux réservoirs en acier non
pressurisés utilisés pour le stockage hors sol de liquides inflammables et combustibles compatibles avec
le matériau de construction et dont la densité ne dépasse pas 1,0. Les réservoirs stockant des liquides
dont la densité est supérieure à 1,0 sont abordés à la sous-section 8.…
Standard for Fire Test For Circuit Integrity Of Fire- Resistive Power, Instrumentation, Control, And...
Scope
1.1 The intent of this Standard is to evaluate the integrity of power, control, instrumentation, and
data/communications cables (such as copper, coaxial, or optical fiber) for their ability to maintain circuit
integrity when subjected to standard fire test exposure and associated hose stream test.
1.2 The power, control, instrumentation, and data/communications cables covered by this…
Norme sur l’essai de tenue au feu pour l’évaluation de l’intégrité du circuit des câbles ignifuges d...
Domaine d’application
1.1 L’objectif de cette norme est d’évaluer l’intégrité des câbles d’alimentation, de commande,
d’instrumentation et de données/communications (tels que les câbles en cuivre, coaxiaux ou à fibres
optiques) pour déterminer leur capacité à maintenir l’intégrité du circuit lorsqu’ils sont soumis à un essai
de tenue au feu standard et à l’essai de tenue à l’eau associé.
1.2…
1 Scope
1.1
This Standard applies to electric vehicle energy management system(s) (EVEMS) product, sub-assemblies of matched assembly systems, and associated software, that provide functional safety control of electrical parameters intended to permit a demand factor to be applied to a calculated load for electric vehicle power transfer system equipment (EVPTSE), rated 1000 Volts ac or 1500…
Cable management systems — Cable ties for electrical installations
Scope
This document specifies requirements for metallic, non-metallic and composite cable ties and their
associated fixing devices as a means used for managing or securing the wiring systems in electrical
installations. Cable ties and associated fixing devices can also be suitable for other applications, such as
support of wiring systems, and where so used, additional requirements can apply…
Scope
This standard applies to consumer tents for outdoor use (including tents intended for both indoor and outdoor use), such as camping tents, backpacking tents, suspended tents, teepees, children’s tents, tent trailers, ice-fishing tents, dining shelters, sun shelters and screen houses.
Note: Examples of children’s tents intended for outdoor use include, but are not limited to, youth camping…
Scope
1.1 Applicability of standard to laboratory fume hoods
This Standard applies to all types of laboratory fume hoods, including ductless fume hoods.
Note: Ductless fume hoods should not be considered acceptable substitutes for ducted fume hoods. They may be suitable alternatives provided there is an application-specific review (i.e., risk assessment) and written approval by the…
Commercial and/or Outdoor Wood- Fired Baking Ovens – Refractory Type
Scope
1.1 These requirements apply to commercial and/or outdoor wood-fired ovens. Commercial wood-fired
ovens are intended for use by commercial establishments for the purpose of cooking or baking food
products utilizing solid wood fuel. These ovens utilize refractory materials as the liner of the oven cavity.
1.2 For the purposes of this Standard, the ovens described in 1.1 that are…
Fours de cuisson à bois commerciaux et/ou extérieurs – type réfractaire
Domaine d’application
1.1 Ces exigences s’appliquent aux fours de cuisson à bois commerciaux et/ou extérieurs. Les fours à
bois commerciaux sont destinés à être utilisés par les établissements commerciaux dans le but de
préparer ou de cuire des produits alimentaires en utilisant du bois massif comme combustible. Ces fours
utilisent des matériaux réfractaires comme revêtement de la cavité du…