CSA C61000-4-13:24
1 Scope and object
This part of IEC 61000 defines the immunity test methods and range of recommended basic
test levels for electrical and electronic equipment with rated current up to 16 A per phase at
disturbance frequencies up to and including 2 kHz (for 50 Hz mains) and 2,4 kHz (for 60 Hz
mains) for harmonics and interharmonics on low voltage power networks.
It does not apply to electrical and electronic equipment connected to 16 2/3 Hz , or to 400 Hz
a.c. networks. Tests for these networks will be covered by future standards.
The object of this standard is to establish a common reference for evaluating the functional
immunity of electrical and electronic equipment when subjected to harmonics and interharmonics
and mains signalling frequencies. The test method documented in this part of IEC
61000 describes a consistent method to assess the immunity of an equipment or system
against a defined phenomenon. As described in IEC guide 107, this is a basic EMC publication
for use by product committees of the IEC. As also stated in Guide 107, the IEC product
committees are responsible for determining whether this immunity test standard should be
applied or not, and if applied, they are responsible for determining the appropriate test levels
and performance criteria. TC 77 and its sub-committees are prepared to co-operate with
product committees in the evaluation of the value of particular immunity tests for their products.
The verification of the reliability of electrical components (for example capacitors, filters, etc.)
is not in the scope of the present standard. Long term thermal effects (greater than 15 min) are
not considered in this standard.
The levels proposed are more adapted for residential, commercial and light industry
environments. For heavy industrial environments the product committees are responsible for
the definition of a class X with the necessary levels. They have also the possibility of defining
more complex waveforms for their own need. Nevertheless, the simple waveforms proposed
have been mainly observed on several networks (flat curve more often for single phase
system) and also on industrial networks (overswing curve more for three phase systems).
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
N/A
Statut:
Norme
Date de Publication:
2024-06-30
Numéro Standard:
CSA C61000-4-13:24