CSA C22.2 No. 96:23

Portable power cables
1 Scope 1.1 This Standard specifies construction and testing requirements for portable power cables normally used in applications where the cables are subject to frequent flexing and where installation is in accordance with CSA M421 and/or the Canadian Electrical Code, Part I, where applicable. 1.2 The cable constructions specified in Clauses 5to 9and Clauses 12to 16of this Standard are suitable for use at a maximum conductor temperature of 90 °C under normal operating conditions in wet or dry locations, outdoors or in underground mines, and in rugged environments. The special cable constructions described in Clauses 10and 11are suitable for use at a maximum conductor temperature of 105 °C. 1.3 This Standard does not specify all types, sizes, and voltage ratings of portable power cables that can be required for particular applications. 1.4 This Standard specifies the following categories of cables: Clause Category 5 Thermoset and PUR multiconductor round cables for mining and general applications rated 5 kV – 35 kV Types: SHD, SHD-BGC (balanced ground check), SHD-GC 6 Thermoset and PUR multiconductor round cables for mining and general applications rated 2 kV Types: W, G, G-BGC (balanced ground check), G-GC, SHC-GC, SHD, SHD-BGC (balanced ground check), SHD-GC, SHD-R 7 Thermoset single-conductor cables for mining and general applications rated 2 kV – 35 kV Types: W, SH 8 Thermoset two- and three-conductor flat cables for mining and general applications rated 2 kV — Suitable for underground applications only Types: G, G-GC, W 9 Thermoset three-conductor round cables with a central bonding conductor for underground coal mining applications rated 2 kV – 5 kV Types: SHD-PCG 10 Arc-welding cable 11 Single-conductor portable power cable rated 600 V Clause Category Types: PPC, PPC/TPE 12 Single and multiconductor portable power cables for general applications rated 600 V – 2 kV Types: PPC, PPC/TPE 13 Flexible multiconductor cable for use with cranes and hoists rated 600 V (festoon cable) 14 Variable frequency drive cable, multiconductor, round, for mining and general applications rated 2 kV – 15 kV Types: VFD, VFD-GC, VFD-BGC (balanced ground check) 15 DLO (diesel locomotive) cable, single conductor, used for portable and general permanent applications rated 2 kV 16 Thermoset and PUR multiconductor round special construction cables for mining and general applications rated 2 kV – 35 kV Types: SHD-SP, SHD-BGC-SP (balanced ground check), SHD-GC-SP 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.6 The values given in SI units are the units of record for the purposes of this Standard.
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
29.060.20
Statut:
Norme
Date de Publication:
2023-09-30
Numéro Standard:
CSA C22.2 No. 96:23