CAN/ULC-S640:2016 (R2022)
1.1 These requirements cover lining systems for new masonry chimneys.
1.2 Liners are for use with gas, liquid and solid fuel fired residential appliances and building heating
equipment, where the flue gas temperatures normally do not exceed 650 °C. They are intended for use
in accordance with the National Building Code of Canada, CSA B139 – Installation Code for Oil Burning
Equipment, CSA B149.1 – Natural Gas and Propane Installation Code Gas Burning Equipment,
CSA B365 – Installation Code for Solid Fuel Burning Appliances and Equipment, and CAN/CSA A405,
Design and Construction of Masonry Chimneys and Fireplaces.
1.3 Liners are intended for field installation in masonry or concrete chimneys located inside or outside of
buildings to provide an essentially vertical conduit or passageway for conveying flue gases to the outer air
from the above described class of appliances.
1.4 Liners as covered by this Standard are intended for installation in accordance with the manufacturer’s
Installation Instructions.
1.5 Liners, as covered by this Standard, are not intended for use with high efficiency appliances that
require type BH gas venting systems, or that create positive pressures in the chimney, unless specifically
listed for such application.
OEN:
ULC
Langue:
English
Code(s) de l'ICS:
91.060.40
Statut:
Norme
Date de Publication:
2016-07-31
Numéro Standard:
CAN/ULC-S640:2016 (R2022)