CAN/CSA-ISO/IEC TR 18047-6:13 (R2017)
1 Scope
This part of ISO/IEC TR 18047 defines test methods for determining the conformance of radio frequency
identification (RFID) devices (tags and interrogators) for item management with the specifications given in
ISO/IEC 18000-6, but does not apply to the testing of conformity with regulatory or similar requirements.
The test methods require only that the mandatory functions, and any optional functions which are
implemented, be verified. This can, in appropriate circumstances, be supplemented by further, applicationspecific
functionality criteria that are not available in the general case.
The interrogator and tag conformance parameters in this part of ISO/IEC TR 18047 are the following:
• type-specific conformance parameters including nominal values and tolerances;
• parameters that apply directly affecting system functionality and inter-operability.
The following are not included in this part of ISO/IEC TR 18047:
• parameters that are already included in regulatory test requirements;
• high-level data encoding conformance test parameters (these are specified in ISO/IEC 15962).
Unless otherwise specified, the tests in this part of ISO/IEC TR 18047 are to be applied exclusively to
RFID tags and interrogators defined in ISO/IEC 18000-6.
Clause 5 describes all necessary conformance tests for ISO/IEC 18000-6 Type A.
Clause 6 describes all necessary conformance tests for ISO/IEC 18000-6 Type B.
Clause 7 describes all necessary conformance tests for ISO/IEC 18000-6 Type C.
Clause 8 describes all necessary conformance tests for ISO/IEC 18000-6 Type D.
Clause 9 describes all necessary conformance tests for ISO/IEC 18000-6 Type C Battery Assisted Passive
(BAP), whereas optional features will only be tested when supported.
Clause 10 describes all necessary conformance tests for ISO/IEC 18000-6 Type C Sensor support, whereas
optional features will only be tested when supported.
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
35.040
Statut:
Annulée
Date de Publication:
2012-12-31
Numéro Standard:
CAN/CSA-ISO/IEC TR 18047-6:13 (R2017)