CAN/CSA-E61241-1-1:02 (R2010)
This National Standard of Canada is based on International Standard IEC
61241-1-1:1999.
1 Scope
This part of IEC 61241 is applicable to electrical apparatus protected by
enclosures and surface temperature limitation for use in areas where
combustible dust may be present in
quantities which could lead to a fire or explosion hazard. It specifies
requirements for design, construction and testing of electrical apparatus.
NOTE - IEC 61241-1-2 gives guidance on the selection, installation and
maintenance of the apparatus. Apparatus within the scope of this standard may
also be subject to additional requirements in other standards - for example,
IEC 60079-0.
The ignition protection is based on the limitation of the maximum surface
temperature of the enclosure and other surfaces which could be in contact with
dust and on the restriction of dust ingress into the enclosure by the use of
"dust-tight" or "dust-protected" enclosures.
The application of electrical apparatus in atmospheres which may contain
explosive gas as well as combustible dust, whether simultaneously or
separately, requires additional protective measures.
Where the apparatus has to meet other environmental conditions, for example,
protection against ingress of water and resistance to corrosion, additional
methods of protection may be necessary. The method used is not to adversely
affect the integrity of the enclosure.
The principles of this standard may also be followed when combustible fibres or
flyings cause a hazard.
This standard does not apply to dusts of explosives which do not require
atmospheric oxygen for combustion, or to pyrophoric substances.
This standard is not applicable to electrical apparatus intended for use in
underground parts of mines as well as those parts of surface installations of
such mines endangered by fire damp and/or combustible dust. This standard does
not take account of any risk due to an emission of flammable or toxic gas from
the dust.
This standard does not include other types of protection and is only applicable
to protection by enclosures and surface temperature limitation.
As the requirements of this Standard cover protection by enclosures and surface
temperature limitation only, this Standard is to be used in conjunction with
other applicable standards containing the appropriate electrical safety
requirements for general use equipment.
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
29.260.20
Statut:
Annulée
Date de Publication:
2002-02-28
Numéro Standard:
CAN/CSA-E61241-1-1:02 (R2010)