CAN/CSA-E79-18-95 (R2009)
This National Standard of Canada is based on International Standard CEI/IEC 79-18:1992.
1 Scope
This part of IEC 79 prescribes the specific requirements for construction and
testing of electrical apparatus, parts of electrical apparatus and Ex
components which have rated voltages not exceeding 11 kV with the type of
protection encapsulation "m".
These specific requirements supplement IEC 79-0 "General Requirements" with the
following exceptions.
Clauses of IEC 79-0 which are not applicable
4.2 Maximum surface temperature (for Ex components)
5.2 Time delay before opening an enclosure
6.2 Threaded holes in enclosures of plastic material
8 Fasteners
9 Interlocking devices
15 Cable and conduit entries
17 Switchgear
18 Fuses
20.2 Warning label for luminaires
22.4.3.1 Test for resistance to impact (for Ex components)
22.4.4 Test for degree of protection for enclosures
22.4.8 Test in explosive mixtures
22.4.9 Test of clamping of non-armoured cables in cable
entries
22.4.10 Test of clamping of armoured cables in cable entries
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
29.260.20
Statut:
Annulée
Date de Publication:
1995-05-30
Numéro Standard:
CAN/CSA-E79-18-95 (R2009)