CAN/CSA-T540-M92
This National Standard of Canada is equivalent to American National Standards
Institute standard ANSI T1.408-1990.
1.1 General
It establishes performance and technical criteria for interfacing and
interconnecting the various functional groups shown in figure 1. Compliance
with this standard is intended to ensure compatibility at the interface points
/a and /b (figure 1) and should not be construed as a constraint on the
internal operation of the network, NTs or TEs. For an interim period¹), as
noted in 5.4.3, equipment that provides a DSX-1 interface arrangement at
reference points S and T, shall be considered as conforming to this standard.
See annex B for characteristics of a DSX-1 interface.
NOTE - The user's attention is called to the possibility that compliance with
this standard may require use of an invention covered by patent rights.
By publication of this standard, no position is taken with respect to the
validity of this claim or of any patent rights in connection therewith. The
patent holder has, however, filed a statement of willingness to grant a license
under these rights on reasonable and nondiscriminatory terms and conditions to
applicants desiring to obtain such a license. Details may be obtained from the
secretariat.
The provisions of this standard are intended to be consistent with applicable
requirements concerning safety and environmental conditions. Customer premises
equipment (CPE) shall be subject to the applicable requirements of UL 1459,
Telephone appliances and equipment²), and of the rules of the Federal
Communications Commission (FCC).
NOTE - Users are advised that CPE for primary rate ISDN may be subject to the
FCC's Part 68 Rules, including the provision of output pulse generation
capability beyond that required by this standard. Equipment manufacturers
should ascertain the applicability of these requirements to their products.
This standard is intended to remain consistent with the American National
Standard for Telecommunications, Carrier to customer installation - DS1
metallic interface specification (DS1 standard), ANSI T1.403-1989. The DS1
standard contains specifications at the network interface (NI) for services
at the DS1 rate.
This primary rate (PR) standard defines specifications at physical interface
points /a and /b (as shown in figure 1). Criteria covered herein include ISDn
channel allocations, framing format, line code requirements, electrical
characteristics, physical requirements, maintenance provisions, and other
necessary criteria for:
- compliance with the electrical specifications at the NI as covered in clause
5 of the DS1 standard, ANSI T1.403. It is important that the electrical
specifications applicable to /a allow for a cable loss of up to 1.5 dB at 772
kHz between /a and the NI as defined in ANSI T1.403, where the associated
equipment is connected to a public network;
- the proper interfacing of interconnected CPE.
1.2 Structure
Most requirements in this standard apply equally to /a and /b. For these
requirements, there is no reference to an interface point and it is to be
understood that the requirements apply at both points. For other
requirements/provisions, the application is explicitly stated. Requirements
applicable at /a and /b imply requirements on the interface cable as stated in
clause 10.
¹) It is expected that this interim provision will be deleted from the next
issue of the standard.
²) This standard is currently under development. Contact the secretariat for
more recent information.
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
33.080
Statut:
Annulée
Date de Publication:
1992-01-30
Numéro Standard:
CAN/CSA-T540-M92