Polyethylene Protective Covering on Paper Insulated Metallic Sheathed Power
Cable
1. Scope
1.1 This Standards applies to polyethylene protective covering over
paper-insulated metallic-sheathed power cables t oprotect the sheath against
mechanical damage during installation and against corrosion.
Note: For abnormal installations, such as when high transient voltages may
appear on the metalic sheath, it may be necessary to require a greater
thickness of polyethylene…
Nominal cross-sectional areas and composition of conductors of insulated cables
Specifies standardized nominal cross-section areas from 0.5 mm2 to 2 000 mm2, numbers and diameters of wires and resistance values of conductors in electric cables and flexible cords.
Classifies conductors for:
1) Cables for fixed installations
- Class 1, solid conductors;
- Class 2, stranded conductors.
2) Flexible copper conductors
- Class 5,
- Class 6 (more flexible than…
Neoprene Protective Covering on Paper Insulated Lead Sheathed Power Cables
1. SCOPE
1.1 This Standard applies to neoprene protective covering over leadsheathed
paper-insulated power cables intended to protect the sheath against mechanical
damage during installation and against corrosion.
1.2 The Standard covers extruded neoprene coverings and also coverings applied
in tape form and fully vulcanized after application.
Note: Neoprene taped covering shall be…
Applies both to capacitor units and capacitor banks intended to be used connected in series with an a.c. transmission or distribution line or circuit forming part of an a.c. power system having a frequency of 15 Hz to 60 Hz. The series capacitor units and banks are usually intended for high voltage power systems. This standard is applicable to the complete voltage range.
Note: For internal…
1. SCOPE
1.1 This Specification applies to complete flue-connected oil burning stoves
incorporating oil burners of the vapourizing-type.
1.2 The requirements given herein apply to circulating and radiant room
heaters, ranges, and combination ranges, as defined in this Specification.
Note: The following related appliances are covered by other CSA Standards:
(a) Mobile hone…
Recommendations for voltage measurement by means of sphere-gaps (one sphere earthed)
Applies to the construction and use of sphere-gaps for measuring the peak value of alternating, direct and both full standard and longer tail impulse voltages. Peak values of the disruptive voltages in air are given in tabular form. Note: - For high-voltage test techniques, see IEC 60.
Active implantable medical devices — Four-pole connector system for implantable cardiac rhythm manag...
This document specifies a four-pole connector system for implantable cardiac rhythm management (CRM) devices which have pacing, electrogram sensing and/or defibrillation functions. This document includes requirements for the connector portion of an implantable lead as well as for the mating connector cavity attached to an implantable pulse generator. Essential dimensions and performance…
Medical electrical equipment — Part 2-90: Particular requirements for basic safety and essential per...
This document applies to the basic safety and essential performance of respiratory high-flow therapy equipment, as defined in 201.3.220, hereafter also referred to as ME equipment or ME system, in combination with its accessories:
— intended for use with patients who can breathe spontaneously; and
— intended for patients who would benefit from improved alveolar gas exchange; and who would…
Road vehicles — Vehicle to grid communication interface — Part 4: Network and application protocol c...
ISO 15118-4:2018 specifies conformance tests in the form of an Abstract Test Suite (ATS) for a System Under Test (SUT) implementing an EVCC or SECC according to ISO 15118-2. These conformance tests specify the testing of capabilities and behaviors of an SUT as well as checking what is observed against the conformance requirements specified in ISO 15118-2 and against what the supplier states the…
Medical electrical equipment — Part 2-61: Particular requirements for basic safety and essential per...
ISO 80601-2-61:2017 applies to the basic safety and essential performance of pulse oximeter equipment intended for use on humans, hereafter referred to as me equipment. This includes any part necessary for normal use, including the pulse oximeter monitor, pulse oximeter probe, and probe cable extender.
These requirements also apply to pulse oximeter equipment, including pulse oximeter monitors,…