Deals with the qualification, application, inspection, testing, handling, and
storage of materials required for plant-applied polyethylene coating applied
externally to bare pipe, whereby an adhesive is interposed between a bare or
epoxy primed pipe and the polyethylene. The coated pipe is primarily intended
for buried or submerged service for oil or gas pipeline systems.
Note: It is not…
This National Standard of Canada is equivalent to International Standard ISo
1561-1975.
This International Standard specifies the classification of, and requirements
for, dental inlay casting wax, together with the test methods to be employed to
determine compliance with these requirements.
Note - Throughout this international standard the figures for SI units are
approximate…
Distributeur à installations de l'abonné - Interface métallique DS1
Vise l'interface métallique entre le distributeur et les installations de
l'abonné (IA), aussi appelée interface réseau (IR), pour le débit DS1. Elle
énonce les critères auxquelles une IR doit satisfaire pour assurer la
compatibilité entre le distributeur et les IA. La norme ne s'applique pas aux
interfaces entre deux distributeurs, entre deux réseaux commutés, entre un…
Procedure for use in the preparation of maximum lamp outlines
Provides guidelines for the preparation of maximum lamp outlines for the specific bulb shapes and caps noted. Is primarily for the use of lamp standardizing committees.
Information Technology - Telecommunications and Information Exchange
Between Systems - End System R...
This National Standard of Canada is equivalent to International Standard
ISO/IEC 10030:1990.
This International Standard defines a protocol for the exchange of routeing
information between an End System and a Subnetwork Address Resolution Entity.
This International Standard is applicable to:
a) End Systems which operate according to the main body of ISO 8878 to provide
and…
Circular Concrete Culvert, Storm Drain, Sewer Pipe, and Fittings
1.1
Pertains to nonreinforced circular concrete pipe and fittings intended to be
used for the conveyance of sewage, industrial wastes, storm water, and for the
construction of culverts.
Note: This Standard is applicable to manufacture and purchase only.
1.2
This Standard establishes the following three strength classifications of
nonreinforced concrete pipe and gives their physical…
Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe, and
Fittings
1.1
Pertains to reinforced circular concrete pipe and fittings intended to be used
for the conveyance of sewage, industrial wastes, and storm water, and for the
construction of culverts.
Note: This Standard is applicable to manufacture and purchase only.
1.2
This Standard pertains to pipe that is intended to be used for jacking
longitudinally in tunnel operations.
Note: Such pipe may…
Precast Reinforced Circular Concrete Manhole Sections, Catch Basins, and
Fittings
1.1
Pertains to precast reinforced circular concrete manhole sections including
base sections, riser sections, catch basins, and appurtenances such as grade
rings, tops, and special sections for use in sewer and water works.
Note: This Standard is applicable to manufacture and purchase only, not
installation.
1.2
The requirements of this Standard are applicable to precast concentric…
Guide for Quality Assurance Programs for Physical and Chemical Testing
Laboratories
1.1
This Special Publication gives guidelines for quality assurance in the
administration and technical operations of a laboratory performing physical or
chemical tests. It is intended to assist in developing their quality assurance
programs. Laboratories wishing to comply with specific requirements may use
these guidelines in conjunction with the requirements where applicable. These…
1. Scope
A257.0
1.1 This Standard describes procedures for testing circular concrete pipe, manhole sections, and joints and includes the following tests:
(a) three-edge bearing test (see Clause 3);
(b) core strength test (see Clause 4);
(c) absorption test (see Clause 5);
(d) hydrostatic test (see Clause 6);
(e) flat slab top test (see Clause 7);and
(f) manhole step test (see…