Scope
1.1 Scope of the B1800 compendium
This Compendium specifies requirements for compounds and for manufactured pipe and pipe fittings, the relevant test methods, and marking requirements, and applies to thermoplastic nonpressure piping including
a)
drain, waste, and vent pipe and pipe fittings;
b)
sewer and storm pipe and pipe fittings; and
c)
accessories such as factory-assembled…
Nanomanufacturing - Key control characteristics - Part 6-4: Graphene-based materials - Surface condu...
IEC TS 62607-6-4:2024 has been prepared by IEC technical committee 113: Nanotechnology for electrotechnical products and systems. It is a Technical Specification.
This second edition cancels and replaces the first edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a)…
Design of nuclear power plants against seismic events — Part 3: Civil structures
This document applies to civil structures of nuclear power plants with water cooled reactors in order to achieve the safety objectives given in ISO 4917-1. For other nuclear facilities the applicability of the document needs to be checked in advance, before it might be applied correspondingly.
This document specifies the requirements for civil structures for the verification of their load-bearing…
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: Genera...
IEC 60227-1:2024 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60227-1:2024 applies to rigid and flexible cables with insulation, and sheath if any, based on polyvinyl chloride…
Household and similar electrical appliances - Safety - Part 2-64: Particular requirements for commer...
IEC 60335-2-64:2021+AMD1:2024 CSV deals with the safety of electrically operated commercial kitchen machines, their rated voltage being not more than 250 V for single phase appliances connected between one phase and neutral, and 480 V for other appliances including direct current (DC) supplied appliances and battery operated appliances. These appliances are not intended for household and similar…
Global maritime distress and safety system (GMDSS) - Part 4: Inmarsat-C ship earth station and Inmar...
IEC 61097-4:2024 CMV contains both the official standard and its commented version. The commented version provides you with a quick and easy way to compare all the changes between IEC 61097-4:2024 edition 4.0 and the previous IEC 61097-4:2012+AMD1:2016+AMD2:2019 CSV edition 3.2. Furthermore, comments from IEC TC 80 experts are provided to explain the reasons of the most relevant changes, or to…
Global maritime distress and safety system (GMDSS) - Part 4: Inmarsat-C ship earth station and Inmar...
IEC 61097-4:2024 specifies the performance requirements and methods of testing for Inmarsat-C ship earth stations (SES) capable of transmitting and receiving direct-printing communications, and for enhanced group call (EGC) receivers, for use in the GMDSS and for use for long-range identification and tracking (LRIT). The available variants are:
Class 0: An EGC receiver, either stand-alone or an…
Information technology — Data centre facilities and infrastructures — Part 6: Security systems
This document specifies requirements and recommendations concerning the physical security of data centres based on the criteria and classifications for “availability”, “security” and “energy efficiency enablement” within ISO/IEC 22237-1.
This document provides designations for the data centre spaces defined in ISO/IEC 22237-1.
This document specifies requirements and recommendations for such data…
Information technology - Data centre facilities and infrastructures - Part 6: Security systems
This document specifies requirements and recommendations concerning the physical security of data centres based on the criteria and classifications for “availability”, “security” and “energy efficiency enablement” within ISO/IEC 22237-1.
This document provides designations for the data centre spaces defined in ISO/IEC 22237-1.
This document specifies requirements and recommendations for such data…
Household and similar electrical appliances - Safety - Part 2-31: Particular requirements for range ...
IEC 60335-2-31:2024 CMV contains both the official standard and its commented version. The commented version provides you with a quick and easy way to compare all the changes between IEC 60335-2-31:2024 edition 6.0 and the previous IEC 60335-2-31:2012+AMD1:2016+AMD2:2018 CSV edition 5.2. Furthermore, comments from IEC TC 61 experts are provided to explain the reasons of the most relevant changes…