STANDARD FOR FIBRE REINFORCED PLASTIC UNDERGROUND TANKS FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS
1 SCOPE
1.1 This Standard sets forth minimum design and construction requirements for fibre reinforced plastic,
non-pressure tanks that are used for the underground storage of flammable and combustible liquids, such
as:
A Petroleum products, including petroleum hydrocarbon fuels with low bio-blends, per
specifications, and similar flammable or combustible liquid petroleum derivatives, such…
STANDARD FOR VOLUMETRIC LEAK DETECTION DEVICES FOR UNDERGROUND AND ABOVEGROUND STORAGE TANKS FOR FLA...
1 SCOPE
1.1 This Standard provides minimum requirements for primary containment leak detection that uses
quantitative assessment of physical characteristics to detect leaks in the primary containment.
1.2 These requirements do not cover qualitative nonvolumetric leak detection devices.
1.3 The requirements of this Standard apply to newly-manufactured products. The requirements of this…
STANDARD FOR NONVOLUMETRIC PRECISION LEAK DETECTION DEVICES FOR UNDERGROUND AND ABOVEGROUND STORAGE ...
1 SCOPE
1.1 This Standard provides minimum requirements for primary containment leak detection that uses
qualitative characteristics to detect leaks in the primary containment.
NOTE: Depending on the design of the tank system, and the capabilities of the leak detection devices, leaks from the
tank alone, and/or from other parts of the tank system, may be detected.
1.2 Nonvolumetric leak…
Occupational health and safety - Hazard identification and elimination and risk assessment and contr...
Scope
1.1 General
This Standard specifies requirements for the identification of OHS hazards, their elimination where practical, and assessment and control of risks associated with remaining hazards.
1.2 Applicability
This Standard is applicable to organizations of any size or type and can be applied at all stages in the lifecycle of a product, process, or service.
1.3 Use
This Standard is…
Electromagnetic compatibility (EMC) — Part 3-3: Limits — Limitation of voltage changes, voltage fluc...
1 Scope
This part of IEC 61000 is concerned with the limitation of voltage fluctuations and flicker
impressed on the public low-voltage system.
It specifies limits of voltage changes which may be produced by an equipment tested under
specified conditions and gives guidance on methods of assessment.
This part of IEC 61000 is applicable to electrical and electronic equipment having an input…
STANDARD CORNER WALL METHOD OF TEST FOR FLAMMABILITY CHARACTERISTICS OF NON-MELTING FOAM PLASTIC BUI...
1 SCOPE
1.1 This method of test for flammability characteristics is applicable to certain low density insulating
materials that do not melt or drip during exposure to fire (see Appendix A). It is used in establishing the
Flame Spread Classification for those foamed plastics whose flammability assessment found in
CAN/ULC-S102, Standard Method of Test for Surface Burning Characteristics of…
Anaesthetic and respiratory equipment — Nebulizing systems and components
*This International Standard specifies requirements for the safety and performance testing of general
purpose nebulizing systems intended for continuous or breath-actuated delivery of liquids, in aerosol
form, to humans through the respiratory system.
This International Standard includes gas-powered nebulizers which can be powered by, e.g.,
compressors, pipeline systems, cylinders, etc., and…
Medical electrical equipment — Deployment, implementation and operational guidelines for identifying...
1 Scope
This Technical Report provides general guidelines for the deployment, implementation and operation of a
screening thermograph intended to be used for individual non-invasive febrile temperature screening of
humans under indoor environmental conditions to prevent the spread of infection.
NOTE The equipment standard for screening thermographs is found in IEC 80601-2-59.
Scope
This International Standard gives guidance on the design and use of environmental performance
evaluation (EPE) within an organization. It is applicable to all organizations, regardless of type, size,
location and complexity.
This International Standard does not establish environmental performance levels.
The guidance in this International Standard can be used to support an organization…
1 Scope
1.1
This Standard applies to expandable sleeving rated at 90°C, 105°C, 125°C, 150°C and 200°C for bundling
of insulated wires and cables, intended for the use in equipment designed to be installed and used in
accordance with the rules of the Canadian Electrical Code, Part I (CE Code). The product consists of an
open weave design of polymeric monofilaments.
1.2
This Standard does not apply…