Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 441 - 450 de 2958
STANDARD METHOD OF FIRE TEST FOR EVALUATION OF INTEGRITY OF ELECTRICAL POWER, DATA AND OPTICAL FIBRE...
1 SCOPE 1.1 The intent of this fire test method is to determine the integrity of electrical power, data and optical fibre cables which are evaluated for their ability to maintain circuit integrity. 1.2 The electrical power, data and optical fibre cables covered by this Standard are installed to comply with the requirements in the Canadian Electrical Code and the National Building Code of Canada.…
Éditeur :
ULC
Statut :
Annulée
Date de publication :
2012-10-31
Code(s) de l'ICS :
29.060.20; 13.220.50
Automatic valves for gas appliances
Scope 1.1 This standard applies to newly produced automatic valves (Section 3, Definitions) constructed entirely of new, unused parts and materials. These valves may be individual automatic valves or valves utilized as parts of automatic gas ignition systems. This standard also applies to commercial/industrial safety shutoff valves (Section 3, Definitions), herein after referred to as C/I…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2012-10-31
Code(s) de l'ICS :
91.140.40
Standard for safety for personnel protection systems for electric vehicle (EV) supply circuits: Gene...
Scope 1.1 These requirements cover devices and systems intended for use in accordance with Annex A, Ref. No. 1, to reduce the risk of electric shock to the user from accessible parts, in grounded or isolated circuits for charging electric vehicles. These circuits are external to or on board the vehicle. 1.2 The devices and systems covered by these requirements are compatible with the designs of…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2012-08-31
Code(s) de l'ICS :
43.040.10
Transfer switch equipment (Tri-national standard, with NMX-J-672 ANCE and UL 1008)
Scope 1.1 This standard applies to: a) Automatic transfer switches; b) Manual or non-automatic transfer switches; c) Closed transition transfer switches; d) Hybrid transfer switches; e) Transfer switches for fire pumps; f) Bypass/isolating switches; g) Softload transfer switches; and h) Transfer switches intended for use as service equipment; that have a maximum rating of 600 volts for…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2012-06-30
Code(s) de l'ICS :
29.120.40
STANDARD METHOD OF FIRE RESISTANCE TEST – GREASE DUCT ASSEMBLIES
1 SCOPE 1.1 This Standard specifies a method of test and criteria for the determination of the fire resistance of grease ducts under standardized fire conditions. The requirements are intended to evaluate the ability of the grease duct to resist the spread of fire. See Appendix A for additional information. 1.2 This Standard also covers requirements to evaluate the ability of the duct to…
Éditeur :
ULC
Statut :
Norme
Date de publication :
2012-05-31
Code(s) de l'ICS :
13.220.50; 13.220.50
STANDARD FOR LINERS USED FOR SECONDARY CONTAINMENT OF ABOVEGROUND FLAMMABLE AND COMBUSTIBLE LIQUID T...
1 SCOPE 1.1 This Standard sets forth minimum requirements for the material properties and performance of liners used for secondary containment under and around the area of tanks that are installed aboveground for the storage of flammable liquids and combustible liquids. 1.2 Liners used for secondary containment are intended for permanent installation to contain spills or leakage of product…
Éditeur :
ULC
Statut :
Norme
Date de publication :
2012-03-31
Code(s) de l'ICS :
23.020.99; 75.160.20
NORME SUR LES MEMBRANES DE CONFINEMENT SECONDAIRE POUR LES RÉSERVOIRS DE STOCKAGE DE LIQUIDES INFLAM...
1 DOMAINE D’APPLICATION 1.1 La présente norme énonce les exigences minimales pour les propriétés et le rendement des matériaux des membranes utilisées pour le confinement secondaire en dessous et autour des réservoirs de stockage de liquides inflammables et de liquides combustibles hors sol. 1.2 Les membranes servant au confinement secondaire sont conçues pour être installées de façon…
Éditeur :
ULC
Statut :
Norme
Date de publication :
2012-03-31
Code(s) de l'ICS :
23.020.99; 75.160.20
STANDARD FOR DRY CHEMICAL FIRE EXTINGUISHERS
1.1 These requirements cover the construction and performance, exclusive of performance during fire tests, of portable dry chemical and dry powder (Class D) fire extinguishers. Dry chemical and dry powder fire extinguishers are intended to be utilized in accordance with the Standard for Portable Fire Extinguishers, ANSI/NFPA 10 and with the National Fire Code of Canada. 1.2 The…
Éditeur :
ULC
Statut :
Annulée
Date de publication :
2012-03-31
Code(s) de l'ICS :
13.220.10
NORME SUR LES EXTINCTEURS À POUDRES CHIMIQUES
1.1 Ces exigences visent la construction et le fonctionnement des extincteurs portatifs à poudre chimique de classe D. Elles ne visent toutefois pas le fonctionnement au cours des essais de réaction au feu. Les extincteurs à poudre chimique sont destinés à être utilisés conformément à la norme ANSI/NFPA 10, Standard for Portable Fire Extinguishers, et au Code national de prévention des…
Éditeur :
ULC
Statut :
Annulée
Date de publication :
2012-03-31
Code(s) de l'ICS :
13.220.10
Air-, cable-, and frame-supported membrane structures
Scope 1.1 This Standard provides requirements for the design, fabrication, installation, and maintenance of single-membrane structures that are either reinforced or unreinforced and that are air-supported, frame-supported, or cable-supported. 1.2 The general requirements, structural design methods, loadings, and limit states specified in this Standard are intended to be consistent with the…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2012-02-29
Code(s) de l'ICS :
91.080.99

Spacer