Firefighters' Protective Clothing for Protection Against Heat and Flame
1. SCOPe
1.1 This standard states the design and performance requirements for
protective clothing worn by firefighters, for protection against heat and flame
encountered during fires and related lifesaving activities, and specifies
methods for testing the materials and material assemblies used in the
protective clothing.
1.2 The standard does not apply to specialized protective…
Methods of Testing Pulp and Paper - Forming Handsheets for Optical Tests of
Pulp (British Sheet Mach...
1. PURPOSE AND SCOPE
1.1 This method describes the procedure for making handsheets for the optical
test methods. It is designed for application to all screened pulps, unbleached
or bleached.
1.2 This method permits the preparation of a smooth and reproducible surface
for optical measurements with a minimum of washing and contamination of the
sample.
1.3 The testing and evaluation of a…
Methods of Testing Pulp and Paper - Pulp, Paper and Paperboard - Colour
Measurement with a Diffuse/Z...
1. PURPOSE AND SCOPE
1.1 This standard specifies a method for measuring the colour of pulp, paper
and paperboard by the diffuse reflectane method.
1.2 This standard is limited to non-fluorescent pulps, papers and paperboards.
1.3 The testing and evaluation of a product against this method may require
the use of materials and/or equipment that could be hazardous. This document
does not…
Standard for Reinforced Plastic Underground Tanks for Flammable and CombustibleLiquids
1. SCOPe
1.1 These requirements cover reinforced plastic non-pressure tanks that are
used for underground storage of flammable and combustible liquids such as
gasoline, diesel fuel, oxygenated motor fuels, aviation fuel, fuel oil, and
lubricating oil. These tanks may be recognized for use with other products
where the tanks have been investigated for such products.
1.2 These…
1. Scope
1.1 This standard applies to latex paint for exterior use on primed wood
and on masonry surfaces including concrete, brick, cinder, stucco,
concrete block and unglazed tile.
1.2 It may be used on unglazed asbestos-cement shingles and siding¹;
however as most asbestos-siding is treated with waterproofing material,
at least one year shall…
1. Scope
1.1 This standard applies to three grades of kerosine type aviation turbine fuel consisting entirely of hydrocarbon compounds, except as otherwise specified. Kerosine Type, Aviation Turbine Fuels are distillates having a minimum flash point of 38°C. Grade JET A has a maximum freezing point of -40°C and Grade JET A-1 and Grade F-34 have a maximum freezing point of -47°C.
1.2 Grade…
Packing of Explosives (Class 1) for Transportation
1. Scope
1.1 This standard sets out the requirements for the transport packaging of
dangerous goods classed as explosives (Class 1 in accordance with the
schedule to the Transportation of Dangerous Goods Act).
1.2 The UN Packing Methods (Appendix A) apply to domestic road, rail and
marine shipment. The IMDG Code applies to international marine
transport…
Performance Packagings for Transportation of Dangerous Goods
1. Scope
1.1 This standard contains design, manufacturing and use requirements for
non-bulk UN specification packagings of no more than 400 kg or 450 l
for the transportation of dangerous goods (other than those classed as
gases, infectious or radioactive).
1.1.1 Part I of this standard applies to classes 1 to 9 excluding classes 2,
6.2 and 7. It…
1. Scope
1.1 This Standard applies to anticorrosive primer suitable for use as a
shop primer or a field primer on ferrous surfaces such as steel bridges
and structural steel where good durability to atmospheric exposure is
required.
1.2 The primer is characterized by easy brushing or spraying on steel, good
penetration into voids (rather than…
1. Scope
1.1 This standard applies to weather-resistant enamel suitable for exterior
use on metal and wood surfaces, with the exception of floors.
1.2 The enamel is intended for exterior use as a topcoat over structural
steel and as a trim finish for wood, and for use on incidental metal.
A particular use is for the identification and marking of fire alarm…