Evaluation of thickness, density and interface width of thin films by X-ray reflectometry — Instrume...
This document specifies a method for the evaluation of thickness, density and interface width of single layer and multi-layered thin films which have thicknesses between approximately 1 nm and 1 μm, on flat substrates, by means of X-Ray Reflectometry (XRR).
This method uses a monochromatic, collimated beam, scanning either an angle or a scattering vector. Similar considerations apply to the case…
This document specifies, for acrylonitrile-butadiene rubbers (NBRs):
— physical and chemical tests on raw rubbers;
— standard materials, a standard test formulation, equipment and processing methods for evaluating the vulcanization characteristics.
The mixing preferred method is the single stage mixing with LIM (laboratory internal mixer).
Medical laboratories — Practical guidance for the estimation of measurement uncertainty
1 Scope
This document provides practical guidance for the estimation and expression of the measurement uncertainty (MU) of quantitative measurand values produced by medical laboratories. Quantitative measurand values produced near the medical decision threshold by point-of-care testing systems are also included in this scope. This document also applies to the estimation of MU for results…
1 Scope
1.1
This Standard provides guidance for the safe use of lasers in health care. It applies to all procedures in health care settings where health care lasers are used, including, but not limited to, the following:
a)
health care facilities;
b)
dental clinics, offices, and facilities;
c)
veterinary facilities;
d)
laboratories and other research facilities;
e)
physician offices…
Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-03...
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replace the existing text with the following:
This part of IEC 61010 specifies safety requirements for hand-held multimeters for domestic
and professional use, capable of measuring MAINS.
Hand-held multimeters are multi-range multifunction measuring instruments intended to
measure…
Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-03...
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replace the existing text with the following:
This part of IEC 61010 specifies safety requirements for HAND-HELD and hand-manipulated
current sensors described below.
These current sensors are for measuring, detecting or injecting current, or indicating current
waveforms on circuits…
Radiological protection — Minimum criteria for electron paramagnetic resonance (EPR) spectroscopy fo...
The purpose of this document is to provide minimum criteria required for quality assurance and quality control, evaluation of the performance and to facilitate the comparison of measurements related to absorbed dose estimation obtained in different laboratories applying ex vivo X-band EPR spectroscopy with human tooth enamel.
This document covers the determination of absorbed dose in tooth enamel…
Radiological protection — Minimum criteria for electron paramagnetic resonance (EPR) spectroscopy fo...
The primary purpose of this document is to provide minimum acceptable criteria required to establish a procedure for retrospective dosimetry by electron paramagnetic resonance spectroscopy and to report the results.
The second purpose is to facilitate the comparison of measurements related to absorbed dose estimation obtained in different laboratories.
This document covers the determination of…
Implants for surgery — Total knee-joint prostheses — Part 1: Determination of endurance properties o...
This document specifies a test method for determining the endurance properties, under specified laboratory conditions, of tibial trays used in knee-joint prostheses to support and secure the plastic articulating surface. It applies to tibial trays which cover both the medial and lateral plateaux of the tibia.
The test method does not apply to tibial components manufactured solely from plastic…
Rice — Determination of amylose content — Part 2: Spectrophotometric routine method without defattin...
This document specifies two simplified routine methods for the determination of the amylose mass fraction of milled rice, non-parboiled. The main difference between the two methods is the dispersion procedure: method A specifies hot dispersion, and method B specifies cold dispersion.
Both methods are applicable to rice with an amylose mass fraction higher than 5 %.
NOTE These methods describe…