CSA C22.2 No. 61010-2-032:20
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replace the existing text with the following:
This part of IEC 61010 specifies safety requirements for HAND-HELD and hand-manipulated
current sensors described below.
These current sensors are for measuring, detecting or injecting current, or indicating current
waveforms on circuits without physically opening the current path of the circuit being
measured. They can be stand-alone current sensors or accessories to other equipment or
parts of combined equipment (see Figure 101). These include measurement circuits which are
part of electrical test and measurement equipment, laboratory equipment, or process control
equipment. These current sensors and circuits need additional protective means between the
current sensor, the circuit and an OPERATOR.
NOTE 1 Combined equipment is equipment that is electrically connected to a current sensor by means of a
permanent connection which can be detached only by the use of a TOOL.
NOTE 2 Some current sensors are also known as current clamps, CLAMP MULTIMETERS and current probes.
Current sensors are hand-manipulated before and/or after a test or measurement, but do not
necessarily need to be HAND-HELD during the test or measurement. Current sensors used as
FIXED EQUIPMENT are not within the scope of this document.
The following types of current sensors are covered:
a) Type A: a current sensor designed to be applied to or removed from HAZARDOUS LIVE
UNINSULATED CONDUCTORS. Type A current sensors have defined HAND-HELD or handmanipulated
parts providing protection against electric shock from the conductor being
measured, and also have protection against short-circuits between wires and between
busbars during clamping.
b) Type B: a current sensor which has protection against short-circuits between wires or
busbars during clamping but without defined HAND-HELD or hand-manipulated parts which
provide protection against electric shock during clamping. Additional protective means are
necessary to avoid electric shock from HAZARDOUS LIVE conductors which cannot be deenergised
during application or removal of the current sensor.
EXAMPLE 1 Flexible current sensors.
c) Type C: a current sensor without protection against short-circuits between wires or
busbars during clamping. Type C current sensors are intended to be applied to or
removed from HAZARDOUS LIVE UNINSULATED CONDUCTORS or from non-limited-energy
circuit conductors only when they are de-energised.
EXAMPLE 2 Split-core transducers.
d) Type D: a current sensor designed to be applied to or removed from insulated conductors
or from limited-energy circuit conductors.
EXAMPLE 3 Current probes for oscilloscopes and earth leakage current detectors.
All current sensors can also be used with insulated conductors. In this case, HAZARDS are
limited to acceptable levels by the insulation of the conductors.
Additional requirements for CLAMP MULTIMETERS are given in Annex EE.
Figure 101 shows graphical representations of typical current sensors for illustration
purposes. Current sensors can look different depending on the design.
Key
1 JAW END(S)
2 JAW
3 Measuring circuit TERMINALS
Figure 101 – Examples of current sensors and their parts
1.2.1 Aspects included in scope
Add the following three new paragraphs at the end of the subclause:
CSA C22.2 No. 61010-2-032:20
This Standard applies to the above-noted equipment that is intended to be installed or used in