Qualification Code for Manufacturers of Structural Glued-Laminated Timber
1 Scope
1.1
Glued-laminated timber (Glulam) is an engineered wood product requiring precise manufacturing at all stages of fabrication. The finished product can only be tested under laboratory conditions; therefore, quality control of manufacturing is necessary to ensure that the properties of Glulam are commensurate with the specified strengths assigned to Glulam in accordance with CAN/CSA-…
Energy performance of food service refrigerators and freezers
Preface
This is the second edition of CSA C827, Energy performance of food service refrigerators and freezers. It supersedes the first edition, published in 1998.
Scope
1.1
This Standard applies to commercial refrigerator, refrigerator-freezer, and freezer cabinets that are intended for storing or holding food products and other perishable merchandise.
1.2
This Standard specifies…
Covers requirements for polyolefin laboratory drainage systems
for corrosive applications. Requirements for materials, pipe,
and fittings are included.
Scope
1.1
This Standard specifies minimum safety and performance requirements for vacuum
devices (see Figure 1). Equipment may be driven by centrally powered piped
vacuum systems, fluids, electricity, or manually powered for a variety of
applications (see Figure 1).
Excluded from the Standard are
(a) central power supply (by vacuum/compressed air generation), piping systems
of…
Testing Procedures for Seismic Qualification of CANDU Nuclear Power Plants
1. Scope
1.1 This Standard defines the consideration and requirements for performing an acceptable seismic qualification test and presents the different test methods that may be used.
Note: Selected safety related systems are required to be seismically qualified. (See CSA Standard CAN3-N289.1.) Qualification may be by analysis or testing, or a combination thereof, depending on the nature…
Medical laboratories — Application of risk management to medical laboratories
1 Scope
This document specifies a process for a medical laboratory to identify and manage the risks to patients, laboratory workers and service providers that are associated with medical laboratory examinations. The process includes identifying, estimating, evaluating, controlling and monitoring the risks.
The requirements of this document are applicable to all aspects of the examinations and…
This National Standard of Canada is equivalent to International Standard ISo
7786:1990.
1 Scope
This International Standard specifies the dimensional and other requirements
for grinding instruments used in the dental laboratory.
Other characteristics of dental abrasive instruments are not covered by this
International Standard. These will be dealt with in a future International…
1 Scope
1.1
This Standard addresses issues related to the safety of human tissues used for transplantation purposes. It includes aspects of safety for potential and actual donors and recipients, personnel, and others who may be exposed to, or affected by, the transplant of tissues.
1.2
This Standard applies to establishments (or facilities) and individuals involved in the donor suitability…
Plume scavenging in surgical, diagnostic, therapeutic, and aesthetic settings
1 Scope
1.1
This Standard applies to systems and equipment used to capture and evacuate plume. It applies to all settings where such systems and equipment are used, including, but not limited to, the following:
(a) surgical facilities;
(b) dental clinics;
(c) medical offices;
(d) veterinary facilities;
(e) laboratories and other research and testing facilities;
(f) cosmetic treatment facilities…
Covers vacuum breakers for use on laboratory faucets in a nominal
pipe size of 3/8 only, although inlet or outlet connections, or
both, may be different when so required for special
installations.