Health informatics — HL7 Personal Health Record System Functional Model, Release 2 (PHR-S FM)
ISO/HL7 16527 PHR-S FM:2016 defines a standardized model of the functions that may be present in PHR Systems.
It is beyond the scope of the PHR system to control the use (or intended use) of PHR data. On the contrary, it is within the scope of the PHR system to manage the authorization of an individual (or other application). Those parties are then responsible for using the data for appropriate (…
Radiological protection — Content of input data for the statistical analysis of dose records of indi...
The objective of this document is to promote the harmonization of data and information reporting formats in order to provide the basis for the evaluation of occupational exposure with a view to allow for benchmarking capacity at the user level, technical review level, country level and global level (such as UNSCEAR) database or register on occupational exposure. Activity sectors and occupations (…
Compressed natural gas refuelling stations installation code
1 Scope
1.1 Inclusions
This Code applies to
a)
the design, location, construction, operation, operator training, and maintenance of CNG vehicle refuelling stations; and
b)
CNG bulk transport filling and decanting stations, including
i)
those that are fixed or mobile and intended for private or public dispensing operations; and
ii)
bulk transport filling and decanting stations that feed…
Liquefied natural gas refuelling stations installation code
1 Scope
1.1 Inclusions
This Code applies to
a)
the design, location, construction, operation, operator training, and maintenance of LNG refuelling stations;
b)
LNG mobile refuelling units (MRUL) or LNG portable refuelling units (PRUL) with single containment storage tanks up to 265 m3 (70 000 gal) water capacity employed for vehicle LNG dispensing operations;
c)
shop-fabricated and…
1 Scope
1.1
This Standard applies to portable luminaires, intended for use in dry, damp, and wet locations, and intended to be used in accordance with the Rules of CSA C22.1, Canadian Electrical Code, Part I, in non- hazardous locations, on a nominal 120 V system and 15 or 20 A branch circuits, or on the load side of a Class 2, LED Class 2, or safety extra-low voltage (SELV) circuit.
1.2
This…
Benchmark energy factor (BEF) for industrial air movement systems
1 Scope
1.1 Inclusions
This Standard is intended for industrial air handling systems with the following characteristics:
a)
systems with energy consumption greater than 500 000 kWh per year;
b)
systems with air flow greater than 9.4 m3/s (20 000 cfm);
c)
air movement systems with a maximum energy output limit of 25 kJ/kg of air, which is equivalent to a maximum pressure ratio of 1.3 per…
Minimum efficiency values for liquid-filled distribution transformers
1 Scope
1.1 General
This Standard specifies energy efficiencies for liquid-filled distribution transformers. The total ownership cost (TOC) methodology is recommended as the means for achieving these energy efficiencies, particularly for use by electric utilities. This Standard also specifies an optimal method for non-utility users, based on a modified TOC methodology that meets the conditions…
Règles de sécurité pour les monte-charges pour personnes
1 Domaine d’application
1.1 Inclusions
Cette norme s’applique aux structures et aux monte-charges qui ne font pas partie intégrante des bâtiments, structures ou autres ouvrages et qui sont destinés à servir pendant la construction, la modification ou la démolition pour faire monter ou descendre des personnes et/ou des matériaux reliés à un project de construction.
Cette norme porte sur la…
1 Scope
1.1
This Standard specifies dimensional and safety requirements for recreational vehicles. Its purpose is to specify minimum criteria for providing a degree of protection against loss of life from fire and explosion.
1.2
The CSA Z240 RV Series of Standards does not apply to park model trailers.
Note: Park model trailers are covered by the CAN/CSA-Z241 Series of Standards.
1.3
The…
Emergency preparedness and response for petroleum and natural gas industry systems
1 Scope
1.1 General
This Standard establishes criteria for emergency preparedness and response for the petroleum and natural gas industry systems.
Note: Prevention, continuity, and recovery are addressed in other standards.
1.2 Applicability
This Standard applies to petroleum and natural gas industry systems (see Figures 1and 2), including
a)
pipeline systems handling
i)
oil;
ii)
gas…