Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 5631 - 5640 de 17198
Fire detection and alarm systems — Part 29: Video fire detectors
ISO/TS 7240-29:2017 specifies requirements, test methods and performance criteria for video fire detectors (VFD), which operate in the visible spectrum, for use in fire detection and alarm systems installed in and around buildings (see ISO 7240‑1). For the testing of other types of VFD working on different principles, ISO/TS 7240-29:2017 can be used only for guidance. Detectors developed for the…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2017-06-13
Code(s) de l'ICS :
13.220.20
Intelligent transport systems — Traffic and travel information (TTI) via transport protocol experts ...
ISO/TS 21219-7:2017 establishes the method of signalling the specific location referencing used by all TPEG2 applications that require detailed location information to be delivered to client devices such as TPEG2-TEC. The TPEG2-location referencing container (TPEG2-LRC) is described and shows how it is used to signal which specific location referencing method is in use for a particular TPEG…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2017-06-13
Code(s) de l'ICS :
03.220.01; 35.240.60
Intelligent transport systems — Traffic and travel information (TTI) via transport protocol experts ...
ISO/TS 21219-22:2017 specifies the logical data format of OpenLRTM location references and general requirements of the method in Clause 6 and defines the structure of the TPEG toolkit for OpenLR location referencing (OLR) in Clauses 7, 8 and 9. The toolkit is intended to be used in the TPEG location referencing container (TPEG-LRC). OpenLR? has been designed for the use case of transferring…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2017-06-13
Code(s) de l'ICS :
03.220.01; 35.240.60
Plastics piping systems — General rules for structural design of glass-reinforced thermosetting plas...
ISO/TS 20656-1:2017 describes how partial factors for buried GRP pipes are developed, and are primarily intended to define the necessary safety measures for GRP pipes that meet the requirements of ISO 10639, ISO 10467 and ISO 25780, and EN 1796 and EN 14364. The same methodology can be utilised for other pipe product standards, although other parameters would apply.
Éditeur :
ISO
Statut :
Publié
Date de publication :
2017-06-12
Code(s) de l'ICS :
23.040.20
Rubber, vulcanized or thermoplastic — Antistatic and conductive products — Determination of electric...
ISO 2878:2017 specifies a method of test to determine the electrical resistance of antistatic and conductive products manufactured wholly or in part from rubber whose electrical resistance measured between defined points, when new, does not exceed 3 × 108 Ω and whose conductivity is derived from the addition of carbon black and/or other appropriate substances to the bulk of the material. NOTE…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2017-06-11
Code(s) de l'ICS :
83.060
Implants for surgery — Wear of total intervertebral spinal disc prostheses — Part 3: Impingement-wea...
ISO 18192-3:2017 defines a test procedure to simulate and evaluate lumbar spinal disc prostheses wear under adverse impingement conditions.
Éditeur :
ISO
Statut :
Publié
Date de publication :
2017-06-11
Code(s) de l'ICS :
11.040.40
Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test a...
IEC 60695-11-2:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 60695-11-2:2017 gives the requirements for the production and confirmation of a nominal 1 kW propane/air pre-…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2017-06-07
Code(s) de l'ICS :
13.220.40
Electric cables - Calculation of the current rating - Part 3-1: Operating conditions - Site referenc...
IEC 60287-3-1:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 60287-3-1:2017 is applicable to the conditions of steady-state operation of cables at all voltages, buried…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2017-06-07
Code(s) de l'ICS :
29.060.20
Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test a...
IEC 60695-11-2:2017 gives the requirements for the production and confirmation of a nominal 1 kW propane/air pre-mixed flame for use in fire hazard testing. This basic safety publication is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51. It is not intended for use by manufacturers…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2017-06-07
Code(s) de l'ICS :
13.220.40
Touch and interactive displays - Part 12-10: Measurement methods of touch displays - Touch and elect...
IEC 62908-12-10:2017(E) specifies the standard measuring conditions and methods for determining touch performance of a touch sensor module. This document is applicable to touch sensor modules, where the structural relationship between touch sensor, touch controller, touch sensor module, display panel, touch display panel, and touch display module is defined in IEC 62908-1-2. The contents of the…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2017-06-07
Code(s) de l'ICS :
31.120