Road vehicles — Liquefied natural gas (LNG) fuel system components — Part 18: Gas temperature sensor
1 Scope
This Standard specifies tests and requirements for the gas temperature sensor, a liquefied natural gas fuel system component intended for use on the types of motor vehicles defined in CSA B109.2 in Canada and NFPA 52 in the U.S.
This Standard also provides general design principles and specifies requirements for instructions and marking.
This Standard is not applicable to the following…
Road vehicles — Liquefied natural gas (LNG) fuel system components — Part 19: Automatic valve
1 Scope
This Standard specifies tests and requirements for the automatic valve, a liquefied natural gas fuel system component intended for use on the types of motor vehicles defined in CSA B109.2 in Canada and NFPA 52 in the U.S.
This Standard also provides general design principles and specifies requirements for instructions and marking.
This Standard is not applicable to the following:
a)…
Information technology — Redfish scalable platforms management API specification — Part 1: Redfish S...
This document defines the required protocols, data model, behaviors, and other architectural components for an interoperable, multivendor, remote, and out-of-band capable interface. This interface meets the cloud-based and web-based IT professionals' expectations for scalable platform management. While large and hyperscale environments are the primary focus, clients can use the document for…
Building automation and control systems (BACS) — Part 5: Data communication protocol
The purpose of this document is to define data communication services and protocols for computer equipment used for monitoring and control of HVAC&R and other building systems and to define, in addition, an abstract, object-oriented representation of information communicated between such equipment, thereby facilitating the application and use of digital control technology in buildings.
Medium-voltage ac contactors, controllers, and control centres
This standard is applicable to ac contactors applied at voltages in the range of 1 501V to 15kV, and
metal-enclosed contactor-based controllers, control centers, and other control assemblies and associated
equipment applied at voltages in the range of 751V to 15kV, designed for operation at frequencies of 50
or 60 Hz on three-phase systems. These requirements cover equipment intended for use…
This document defines three CIE standard illuminants for use in colorimetry: CIE standard illuminant A for the representation of typical tungsten-filament lighting, CIE standard illuminant D65 for the representation of average daylight having a correlated colour temperature of approximately 6 500 K and CIE standard illuminant D50 for the representation of daylight with a correlated colour…
Railway applications — Track geometry quality — Part 1: Characterization of track geometry and track...
This document defines track geometry parameters and specifies the minimum requirements for track geometry measurements and the evaluation method for track geometry quality.
This document is applicable to 1 435 mm and wider track gauges. The urban/light rail systems, tramways and any track gauge narrower than 1 435 mm are excluded from the scope of this document, however it can be used as a…
Non-destructive testing — Characterization and verification of ultrasonic phased array equipment — P...
This document specifies the functional characteristics of multi-channel ultrasonic phased array instruments used for array probes and provides methods for their measurement and verification.
This document is also applicable to ultrasonic phased array instruments in automated systems; but other tests can be needed to ensure satisfactory performance. When the phased array instrument is a part of an…