Defines the terms used in the heat treatment of ferrous products. The vocabulary is divided into a main part and a complementary section. The complementary section contains the definitions of terms necessary to understand the main part.
Information technology - Protocol for providing the connectionless-mode network service - Part 2: Pr...
Differs from the other related International Standards by the layers defined in ISO/IEC 7498-1. In particular, it defines the way in which a local area network that conforms to ISO/IEC 8802 may be used as a subnetwork within the network layer to provide the abstract underlying service with respect to which the protocol defined by ISO/IEC 8473-1 is specified.
Information technology — Telecommunications and information exchange between systems — Private Integ...
Deals with the service specification functional model and information flows applicable to Private Integrated Services Network (PISN). Uses the ISDN concepts as developed by ITU T (formerly CCITT) and is also within the framework of standards for Open Systems Interconnection (OSI) as defined by ISO.
Information technology - Telecommunications and information exchange between systems - Private Integ...
Deals with the service specification functional model and information flows applicable to Private Integrated Services Network (PISN). Uses the ISDN concepts as developed by ITU T (formerly CCITT) and is also within the framework of standards for Open Systems Interconnection (OSI) as defined by ISO.
Surge arresters - Part 5: Selection and application recommendations - Section 1: General
Provides recommendations for the selection and application of surge
arresters to be used in three-phase systems with nominal voltages
above 1kV. It applies to non-linear resistor type gapped surge
arresters as defined in IEC 60099-1 and to gapless metal-oxide surge
arresters as defined in IEC 60099-4.
The contents of the corrigendum of April 1996 have been included in this copy.
Information technology — International Standardized Profile — Common upper layer requirements — Part...
Specifies a profile of the minimal OSI facilities supporting basic connection-oriented communications applications. These facilities are comprised of a subset of the facilities defined by ACSE, Presentation, and Session service definitions.
Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environme...
This section of IEC 61000-2 defines the high-altitude electromagnetic pulse (HEMP) environment that is one of the consequences of a high-altitude nuclear explosion. Those dealing with this subject consider two cases: - high-altitude nuclear explosions; - low-altitude nuclear explosions. For civil systems, the most important case is the high-altitude nuclear explosion. In this case, the other…
Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Sp...
This part of 61000-5 defines how protective devices for conducted disturbance proposed for HEMP protection shall be specified. It is intended to be used for the harmonization of existing or future specifications issued by protective device manufacturers, electronic equipment manufacturers, administrations and other ultimate buyers. Performance requirements shall be given in future IEC documents.…