Industrial communication networks - Fieldbus specifications - Part 3-4: Data-link layer service defi...
IEC 61158-3-4:2023 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term "time-critical" is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window…
Industrial communication networks - Fieldbus specifications - Part 5-26: Application layer service d...
IEC 61158-5-26:2023 provides common elements for basic time-critical and non-time-critical messaging communications between application programs in an automation environment and material specific to Type 26 fieldbus. The term "time-critical" is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level…
Industrial communication networks - Fieldbus specifications - Part 3-4: Data-link layer service defi...
IEC 61158-3-4:2023 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term "time-critical" is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time window…
Industrial communication networks - Fieldbus specifications - Part 3-24: Data-link layer service def...
IEC 61158-3-24:2023 provides common elements for basic time-critical messaging communications between devices in an automation environment. The term "time-critical" is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level of certainty. Failure to complete specified actions within the time-window…
Industrial communication networks - Fieldbus specifications - Part 5-26: Application layer service d...
IEC 61158-5-26:2023 provides common elements for basic time-critical and non-time-critical messaging communications between application programs in an automation environment and material specific to Type 26 fieldbus. The term "time-critical" is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level…
Industrial communication networks - Fieldbus Specifications Part 6-27: Application layer protocol sp...
IEC 61158-6-27:2023 provides common elements for basic time-critical and non-time-critical messaging communications between application programs in an automation environment and material specific to Type 27 fieldbus. The term "time-critical" is used to represent the presence of a time-window, within which one or more specified actions are required to be completed with some defined level…
Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specificatio...
IEC 61156-1:2023 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61156-1:2023 specifies the definitions, requirements and test methods of multicore, symmetrical pair and quad…
Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specificatio...
IEC 61156-1:2023 specifies the definitions, requirements and test methods of multicore, symmetrical pair and quad cables. This document is applicable to communication systems such as local area networks (LANs) and data communication cables. It is also applicable to cables used for industrial applications, customer premises wiring and generic cabling comprising installation cables and cables for…
This document specifies requirements for the field of vision from the defined working positions on the bridge of large yachts.
It is applicable to large yachts with a length of 24 m or over.
NOTE This document supports the aims of SOLAS, Chapter V, Regulation 22.
Information technology — Data centres key performance indicators — Part 7: Cooling efficiency ratio ...
This document specifies the cooling efficiency ratio (CER) as a key performance indicator (KPI) for quantifying the efficient use of energy to control the temperature of spaces within a data centre (DC).
This document:
a) defines the CER of a DC;
b) describes the relationship of this KPI to a DC’s infrastructure, information technology equipment and information technology operations;
c) …