Information technology - Plenoptic image coding system (JPEG Pleno) - Part 5: Holography
This document defines the syntax and an accompanying decompression process that is capable of representing binary and continuous-tone holograms while supporting one or multiple color/spectral components. The supported compression mechanisms are lossless for binary holograms and lossy for continuous-tone holograms. Additional information on the encoding tools is provided as well. The document also…
Electrical installations in ships - Part 378: Optical fiber cables
IEC 60092-378:2024 is applicable to shipboard and offshore optical fibre cables, intended for fixed installations.
Cables designed to maintain functional integrity during fire given in 6.1 and to be installed in explosive atmospheres given in 6.2 are included.
The various types of optical fibre cables are given in Clause 6. The constructional requirements and test methods are aligned with those…
Luminaires - Part 1: General requirements and tests
IEC 60598-1:2024 specifies general safety requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Requirements for semi-luminaires are included in this document.
This tenth edition cancels and replaces the ninth edition published in 2020. This edition constitutes a technical revision.
This edition includes the following significant…
Luminaires - Partie 1: Exigences générales et essais
L'IEC 60598-1:2024 spécifie les exigences de sécurité générales pour les luminaires qui incorporent des sources de lumière électriques destinées à fonctionner avec des tensions d'alimentation jusqu'à 1 000 V. Les exigences relatives aux semi-luminaires sont incluses dans le présent document.
Cette dixième édition annule et remplace la neuvième édition parue en 2020. Cette édition…
Nanotechnologies — In vitro acute nanoparticle phototoxicity assay
This document specifies a procedure to evaluate acute phototoxicity of nanoparticles (NPs), suspended in cell culture media, by measuring the relative reduction in cellular viability under near ultraviolet (UVA) exposure (315 nm to 400 nm).
The measurement is intended to assess the potential for acute phototoxicity of NPs by comparing NP photoactivity in vitro to a positive control chlorpromazine…
Artificial intelligence — Data quality for analytics and machine learning (ML) — Part 2: Data qualit...
This document specifies a data quality model, data quality measures and guidance on reporting data quality in the context of analytics and machine learning (ML).
This document is applicable to all types of organizations who want to achieve their data quality objectives.
Microbiology of the food chain — Method validation — Part 7: Protocol for the validation of identifi...
This document specifies the general principle and the technical protocol for the validation of identification methods of microorganisms for microbiology in the food chain. As there is no reference method, no method comparison study can be run. Therefore, this document provides a protocol to evaluate the performance characteristics and validate the method workflow using well-defined strains. When…
Microbiologie de la chaîne alimentaire — Validation des méthodes — Partie 7: Protocole pour la valid...
Le présent document spécifie le principe général ainsi que le protocole technique pour la validation de méthodes d’identification des micro-organismes dans le domaine de la microbiologie de la chaîne alimentaire. Dans la mesure où il n’existe pas de méthode de référence, une étude de comparaison des méthodes ne peut être entreprise. Par conséquent, le présent document fournit un protocole pour…
Vegetable fats and oils — Determination of aflatoxins B1, B2, G1 and G2 by immunoaffinity column cle...
This document specifies a method for the determination of the aflatoxins B1, B2, G1 and G2 in vegetable fats and oils, including peanut oil, sesame oil, olive oil, corn oil, sunflower oil, rapeseed oil and coconut oil, using immunoaffinity column clean-up and high-performance liquid chromatography with post-column derivatization.
The limits of quantification for the aflatoxins B1, B2, G1 and G2,…