1 Scope
1.1
This Standard provides minimum requirements for the manufacture of glulam of those species specified in CSA O86. It also provides minimum requirements for the block-gluing and re-gluing of glulam components into larger finished glulam.
1.2
Storage, handling, and installation of products subsequent to manufacture are not covered by this Standard.
1.3
The design criteria for…
Intelligent building systems objective-based Code (IBSC) This
1 Scope
1.1 General
This Code specifies objective-based requirements for system interoperability and for the safety, security, and privacy of persons and/or property against vulnerabilities of an intelligent building system (IBS) network. This Code also specifies requirements for resource efficiency and indoor air quality.
This Code outlines operational requirements for IBS networks in…
Code des systèmes de bâtiment intelligent axé sur les objectifs (IBSC)
1 Domaine d’application
1.1 Généralités
Le présent code définit des exigences fondées sur des objectifs pour l’interopérabilité des systèmes ainsi que pour la sûreté, la sécurité et la protection de la vie privée des personnes et/ou des biens contre les vulnérabilités d’un réseau de systèmes de bâtiments intelligents (IBS). Le présent code précise également les exigences relatives à l’…
L’ergonomie au bureau — Une norme d’application pour l’ergonomie des postes de travail
1 Domaine d’application
1.1 Inclusions
La présente norme prescrit les exigences relatives à l’application de l’ergonomie dans les bureaux. Elle s’applique à tous les employés de bureau travaillant dans des espaces de travail de bureau dans des bâtiments neufs ou existants et dans des bureaux à domicile. Elle comprend également des exigences et des conseils relatifs aux autres espaces de travail…
1 Domaine d’application
1.1 Généralités
La présente norme identifie les activités professionnelles et les compétences professionnelles qui les appuient requises des paramédics au Canada. Elle reflète les pratiques actuelles et émergentes au Canada.
La présente norme fournit également des conseils et des précisions pour faciliter la compréhension et l’utilisation de la norme, y compris une vue…
Safety of transformers, reactors, power supply units and combinations thereof — Part 2-13: Particula...
1 Scope
Replacement:
This part of IEC 61558 deals with the safety of auto-transformers for general applications and
power supply units incorporating auto-transformers for general applications. Transformers
incorporating electronic circuits are also covered by this document.
NOTE 1 Safety includes electrical, thermal and mechanical aspects.
Unless otherwise specified, from here onward, the…
Safety of transformers, reactors, power supply units and combinations thereof — Part 2-2: Particular...
1 Scope
Replacement:
This part of IEC 61558 deals with the safety of control transformers and power supply units
incorporating control transformers. Transformers incorporating electronic circuits are also
covered by this document.
NOTE 1 Safety includes electrical, thermal and mechanical aspects.
Unless otherwise specified, from here onward, the term transformer covers control
transformers…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
IEC 61010-1:2010, Clause 1 and IEC 61010-1:2010/AMD1:2016, Clause 1 apply except as
follows:
1.1.1 Equipment included in scope
Replace the existing text with the following:
This document specifies safety requirements for hand-held multimeters and other meters for
domestic and professional use, capable of measuring MAINS.
Hand-held multimeters are multi-range…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
IEC 61010-1:2010, Clause 1 and IEC 61010-1:2010/AMD1:2016, Clause 1 apply except as
follows:
1.1.1 Equipment included in scope
Replace the existing text with the following:
This document specifies safety requirements to equipment for measuring insulation resistance
and to equipment for testing electric strength which have an output voltage exceeding 50 V a.c.
or 120 V d.…
Évaluation du facteur énergétique de référence (FÉR) des installations réfrigérées
1 Domaine d’application
1.1 Inclusions
La présente norme vise les installations réfrigérées ayant les caractéristiques suivantes :
a)
l’entreposage réfrigéré et des installations réfrigérées de transformation pour les produits alimentaires et les boissons;
b)
un cycle à compression de vapeur et assurant le refroidissement par convection ou par conduction;
c)
un volume de zone réfrigérée…