Mobile elevating work platforms — Design, calculations, safety requirements and test methods
verification, for all types and sizes of mobile elevating work platforms (MEWPs) intended for moving persons to
working positions. It gives the structural design calculations and stability criteria, construction, safety
examinations and security tests to be applied before a MEWP is first put into service, identifies the hazards
arising from the use of MEWPs and describes methods for the…
Plates-formes élévatrices mobiles de personnel — Conception, calculs, exigences de sécurité et métho...
1DV.1
[Modifier le chapitre 1 en remplaçant la dernière phrase du premier paragraphe par ce qui suit]
Elle fournit les calculs de conception de la structure et les critères de stabilité, la construction, les
examens et les essais de sécurité à appliquer avant la première mise en service des PEMP.
1DV.2
[Modifier le chapitre 1 en ajoutant ce qui suit]
Cette norme est considérée comme…
Mobile elevating work platforms — Safety principles, inspection, maintenance and operation
This International Standard applies to all mobile elevating work platforms (MEWPs) that are
intended to position persons, tools and materials and which, as a minimum, consists of a work
platform with controls, an extending structure and a chassis.
The technical safety requirements of this International Standard apply except where national or
local regulations are more stringent.
For related…
Mobile elevating work platforms — Operator (driver) training
This International Standard provides methods for preparing training materials and administering
standardized training to operators (drivers) of mobile elevating work platforms (MEWPs).
It is applicable to MEWPs, as defined in ISO 16368, intended to move persons, tools and materials to
positions where they can carry out work from the work platform.
NOTE National or other regulations, which…
Plates-formes élévatrices mobiles de personnel — Formation des opérateurs (conducteurs)
1DV.1
[Remplacer le titre de l’article 1 par «Domaine d’application, but et application»]
1DV.2
[Ajouter ce qui suit à l’article 1]
Dans cette norme, lorsqu’il est fait référence à l’ISO 16368, CAN/CSA-B354.6 sera considérée comme
respectant l’esprit de l’ISO 16368.
Dans cette norme, lorsqu’il est fait référence à l’ISO 18893, CAN/CSA-B354.7 sera considérée comme
respectant l’esprit de l’…
1.1
This Standard applies to cord-connected and permanently connected electrically heated commercial cooking appliances for use on nominal system voltages of 600 V and less, that are intended to be used in accordance with CSA C22.1, Canadian Electrical Code, Part I.
1.2
This Standard applies to electric ranges, ovens, broilers, fry kettles, griddles, sandwich toasters, toasters, food warmers,…
1.1
This Standard covers the electrical, fire, and shock hazard requirements for all permanently and cord- connected signal equipment intended for household, commercial and industrial use operating at
a)
nominal system voltage of 120 V for household use;
b)
nominal system voltages up to 600 V for commercial and industrial use; and
c)
double insulated equipment up to 240 V.
in non-…
1.1
This Standard applies to cords and cord sets intended for indoor use to electrically connect communication systems that have a normal operating voltage-to-ground of less than 150 V, and that are installed or used in accordance with the Rules of the Canadian Electrical Code, Part I.
1.2
This Standard applies to single-, paired-, and multi-conductor cords, as well as cord sets, where no part…
Explosive atmospheres — Part 30-1: Electrical resistance trace heating — General and testing require...
The requirements of the IEC 60079 series of Standards cover protection with respect to explosion
hazard only. The CAN/CSA-C22.2 No. 60079 series of Standards (based on the adoption of the
corresponding IEC Standards) is to be used in conjunction with other applicable Standards containing
the appropriate electrical safety requirements for general use equipment.
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1.1.1 Scope
Replacement:
This Part 2 is applicable to electrically powered LABORATORY CENTRIFUGES.
This group safety publication is primarily intended to be used as a product safety standard for
the products mentioned in the scope, but shall also be used by technical committees in the
preparation of its publications for products similar to those mentioned in the scope of this