Affiner les résultats
Affichage de 757 - 768 de 1376
Avis d'intention
Allied Health Education Standard
Remarque : Le code ICS de ce NOI a été mis à jour par l'OEN responsable le 23 avril 2024. HSO's Allied Health Education Standard aims to ensure the efficiency and effectiveness of educational programs in designated health...
Avis d'intention
Tubes électriques non métalliques
This Standard applies to corrugated electrical nonmetallic tubing (ENT) and mechanically- attached fittings, for use in accordance with C22.1, Canadian Electrical Code, Part I (CEC), and NFPA 70, National Electrical Code (NEC...
Avis d'intention
Conduit non métallique flexible étanche aux liquides
1.1 These requirements cover liquid-tight flexible nonmetallic conduit in the 3/8 – 4 (12 – 103) trade sizes of Type LFNC-A (Layered), Type LFNC-B (Integral), and Type LFNC-C (Corrugated) constructions. The conduit is...
Avis d'intention
Norme sur les unités de système d'extinction ...
These requirements cover the construction and operation of fixed condensed aerosol extinguishing system units inclusive of aerosol generating extinguishing system units and aerosol generating automatic extinguisher units...
Avis d'intention
Norme sur les extincteurs au dioxyde de carbone
Ces exigences visent la construction et le fonctionnement des extincteurs portatifs au dioxyde de carbone. Elles ne visent toutefois pas le fonctionnement au cours des essais de réaction au feu. Les extincteurs au dioxyde de...
Avis d'intention
Mise en service de bâtiments existants pour les...
La présente norme fournit des lignes directrices pour la mise en service des systèmes d'énergie et d'eau dans les bâtiments existants, tels que définis dans la partie 3 du Code national du bâtiment du Canada (CNB). La...
Avis d'intention
Busway
1.1.1 This Standard applies to service-entrance, feeder, and branch-circuit busways and associated fittings rated at 600 V or less, 6 000 A or less, and intended for use in accordance with the Canadian Electrical Code, Part I...
Avis d'intention
Busways
1.1.1 This Standard applies to service-entrance, feeder, and branch-circuit busways and associated fittings rated at 600 V or less, 6 000 A or less, and intended for use in accordance with the Canadian Electrical Code, Part I...
Avis d'intention
Busways
1.1.1 This Standard applies to service-entrance, feeder, and branch-circuit busways and associated fittings rated at 600 V or less, 6 000 A or less, and intended for use in accordance with the Canadian Electrical Code, Part I...
Avis d'intention
Standard for Factory-Built Grease Ducts
These requirements cover factory-built grease ducts and grease duct assemblies that are intented to be installed as alternatives to the grease ducts constructed of all welded 1.37 mm carbon steel or 1.09 mm stainless steel...
Avis d'intention
Norme sur les extincteurs aux agents propres ...
1 Domaine d'application 1.1 Ces exigences visent la construction et le fonctionnement des extincteurs portatifs aux agents propres à l'halocarbure. Elles ne visent toutefois pas le fonctionnement au cours des essais de...
Avis d'intention
Norme sur les extincteurs aux agents propres ...
1 Domaine d'application 1.1 Ces exigences visent la construction et le fonctionnement des extincteurs portatifs aux agents propres à l'halocarbure. Elles ne visent toutefois pas le fonctionnement au cours des essais de...
Spacer