Affiner les résultats
Affichage de 5137 - 5148 de 9350
Avis d'intention
Technologies de l'information — Architecture ...
Today multi-screen/second-screen solutions are proliferating. However, each is a proprietary vertical for particular vendor(s). Therefore users expectations aren’t being met: Seamless interoperability across vendors. Ability...
Avis d'intention
Technologies de l'information — Architecture ...
This document specifies the characteristics of the UPnP networked service named ApplicationManagement, version 1. This service definition is compliant with UPnP Device Architecture 1.0 [1]. This service type enables to manage...
Avis d'intention
Technologies de l'information - Architecture ...
This service definition is compliant with the UPnP Device Architecture version 1.0. It defines a service type referred to herein as FriendlyInfoUpdate service . It is scoped to the Device Description Document (DDD) and is a...
Avis d'intention
Technologies de l'information — Architecture ...
This service definition is compliant with [1]. It defines a service type referred to herein as the CallManagement service. The CallManagement service is a UPnP service that allows control points to use the telephony features...
Avis d'intention
Viroles nues et couvertes
1.1 These requirements cover bare and covered ferrules intended for field wiring and factory wiring for use in accordance with the National Electrical Code, ANSI/NFPA-70 and Canadian Electrical Code, CSA C22.1. 1.2 These...
Avis d'intention
Éoliennes – Partie 11: Techniques de mesure ...
This part of IEC 61400 presents measurement procedures that enable noise emissions of a wind turbine to be characterised. This involves using measurement methods appropriate to noise emission assessment at locations close to...
Avis d'intention
Code du bâtiment: technologies de l’information...
This code and associated standards will specify the requirements for information and communication technology infrastructure and equipment operating or intended to operate as communications and digital networks for buildings...
Avis d'intention
Méthode d'essai pour l'évaluation des connecteurs...
This standard provides basic procedures based on joint ultimate load or a limiting slip for the determination of the lateral strength resistance and lateral slip resistance of truss pate teeth embedded in sawn and structural...
Avis d'intention
Equipement de chauffage industriel
.1 This Standard specifies the requirements for cord-connected and permanently connected, industrial type heating equipment intended to be used in ordinary locations in accordance with CSA C22.1, Canadian Electrical Code...
Avis d'intention
Fiches, prises et connecteurs industriels spéciaux...
1.1 This Standard applies to locking type plugs, receptacles, equipment power inlets and outlets, and connectors rated up to 60 A and up to 600 V ac or 250 V dc, for use in accordance with the Canadian Electrical Code, Part I...
Avis d'intention
Construction et essai des chauffe-eau électriques...
1.1 This Standard applies to both cord-connected and permanently connected storage-tank water heaters, having tanks less than 610 mm inside diameter, for use on nominal system voltages of 600 V and less, and designed to be...
Avis d'intention
Technologies de l’information — Codage à haute...
This document provides accompanying reference software for Rec. ITU-T H.265 | ISO/IEC 23008-2 as an electronic attachment. The software is an integral part of this document. The use of this reference software is not required...
Spacer