CSA C80079-36:22
1 Scope
This part of ISO/IEC 80079 specifies the basic method and requirements for design,
construction, testing and marking of non-electrical Ex equipment, Ex Components, protective
systems, devices and assemblies of these products that have their own potential ignition
sources and are intended for use in explosive atmospheres.
Hand tools and manually operated equipment without energy storage are excluded from the
scope of this standard. This standard does not address the safety of static autonomous
process equipment when it is not part of equipment referred to in this standard.
NOTE 1 Static autonomous process equipment includes items such as tanks, vessels, fixed pipework and hand
operated valves which do not have their own source of energy that could create a potential ignition source during
operation.
This standard does not specify requirements for safety, other than those directly related to the
risk of ignition which may then lead to an explosion. The standard atmospheric conditions
(relating to the explosion characteristics of the atmosphere) under which it may be assumed
that equipment can be operated are:
• temperature -20 °C to +60 °C;
• pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and
• air with normal oxygen content, typically 21 % v/v.
Such atmospheres can also exist inside the equipment. In addition, the external atmosphere
can be drawn inside the equipment by natural breathing produced as a result of fluctuations in
the equipment’s internal operating pressure, and/or temperature.
NOTE 2 Although the standard atmospheric conditions above give a temperature range for the atmosphere of -
20 °C to +60 °C, the normal ambient temperature range for the equipment is -20 °C to +40 °C, unless otherwise
specified and marked. It is considered that -20 °C to +40 °C is appropriate for most equipment and that to
manufacture all equipment to be suitable for a standard atmosphere upper ambient temperature of +60 °C would
place unnecessary design constraints.
NOTE 3 The requirements of this standard can also be helpful for the design, construction, testing and marking of
equipment intended for use in atmospheres outside the validity range stated above. In this case however, the
ignition hazard assessment, ignition protection provided, additional testing (if necessary), manufacturer’s technical
documentation and instructions to the user, clearly demonstrate and indicate the equipment’s suitability for the
conditions it may encounter. It is also recognized that changes in temperature and pressure can have a significant
influence on characteristics of the explosive atmosphere, such as ignitability.
This part of ISO/IEC 80079 specifies the requirements for the design and construction of
equipment, intended for explosive atmospheres in conformity with all Equipment Protection
Levels (EPLs) of Group I, II and III.
NOTE 4 It is not unusual for equipment designed and constructed in accordance with this standard for a particular
EPL to be used in areas requiring an EPL with a higher level of safety by including the application of additional
measures. Such measures include for example inerting, suppression, venting or containment or for example by
dilution, drainage, monitoring and shut-down. Such measures are outside the scope of this standard.
This standard supplements and modifies the general requirements of IEC 60079-0, as shown
in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0,
as far as applicable for non-electrical equipment, the requirement of this standard takes
precedence.
This standard is supplemented or modified by the following standards concerning specific
types of protection:
– ISO 80079-37, Explosive atmospheres – Part 37: Non-electrical equipment for explosive
atmospheres – Non-electrical type of protection constructional safety "c", control of
ignition source "b", liquid immersion "k"
– IEC 60079-1, Explosive atmospheres – Part 1: Equipment protection by flameproof
enclosures "d"
– IEC 60079-2, Explosive atmospheres – Part 2: Equipment protection by pressurized
enclosures "p"
– IEC 60079-31, Explosive atmospheres – Part 31: Equipment dust ignition protection by
enclosure "t"
The nature and ignition sources of non-electrical equipment shall be considered when
applying types of protection "d", "p", or "t" on non-electrical equipment (see Annex G).
The requirements of the ISO/IEC 80079 series of Standards cover protection with respect to explosion
hazard only. The CSA C80079 series of Standards (based on the adoption of corresponding ISO/IEC
Standards) may be used in conjunction with other applicable Standards containing the appropriate
electrical safety requirements for general use equipment.
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
13.230;
29.260.20
Statut:
Norme
Date de Publication:
2022-11-30
Numéro Standard:
CSA C80079-36:22