CAN/ULC-S712.1:2021
1.1 This Standard specifies the physical property requirements and test methods to determine the
material properties for light density, open cell spray applied semi-rigid polyurethane foam, used as a
thermal insulation for building applications, whether applied on a building site or in a prefabrication
(manufacturing) facility.
1.2 The spray polyurethane foam system installer site manufactures the light density, open cell spray
applied semi-rigid polyurethane foam material identified by this Standard. The spray polyurethane foam
system supplier produces a liquid “resin” component and supplies the corresponding polymeric isocyanate
which, when mixed together on a fixed ratio basis, produce the material which results in the physical
properties listed in this Standard. The Standard CAN/ULC-S712.2 includes mandatory requirements for
the installation of the material as well as qualification of contractors and the qualification of installers and
forms an integral part of the manufacturing process for the finished material.
1.3 The test methods listed in this Standard are used to determine the values for the physical properties.
These physical property values are intended for use in specifications, material evaluations and quality
control. They are not intended to predict end-use material performance.
1.4 This standard applies to material where the continuous service temperature of the substrate is within
the range of -60 to +70 °C.
1.5 The testing and evaluation of a material against this Standard may require the use of materials
and/or equipment that could be hazardous. This Standard does not purport to address all the safety
aspects associated with its use. Anyone using this Standard has the responsibility to consult the
appropriate authorities and to establish appropriate health and safety practices in conjunction with any
existing applicable regulatory requirements prior to its use.
OEN:
ULC
Langue:
English
Code(s) de l'ICS:
91.120.10
Statut:
Norme
Date de Publication:
2021-11-29
Numéro Standard:
CAN/ULC-S712.1:2021