CAN/ULC-S743.2:2021
1 Scope
1.1 This document specifies the requirements for the on-site manufacture and installation of low
pressure applied two component spray polyurethane foam to produce a material that meets the physical
property requirements of CAN/ULC-S743.1, Standard for Thermal Insulation – Low Pressure Applied Two
Component Spray Polyurethane Foam, Part 1: Material Specification. The material only has the physical
properties listed in CAN/ULC-S743.1 when it is installed on-site in accordance with this document. This
document applies to the manufacture and installation of low pressure applied two component spray
polyurethane foam whether applied on a building site or in a prefabrication (manufacturing) facility.
1.2 The spray polyurethane foam system installer site-manufactures the low pressure applied two
component spray polyurethane foam material identified by CAN/ULC-S743.1. The spray polyurethane
foam system supplier produces a liquid resin component and supplies the corresponding polymeric
isocyanate. When mixed together on a fixed ratio basis, these two components produce the material which
possesses the physical properties listed in CAN/ULC-S743.1. This document includes mandatory
requirements for the installation of the material as well as qualification of contractors and the qualification
of installers which form an integral part of the manufacturing process to produce the finished material.
1.3 There are requirements for the supplier, the contractor and the installer provided in this document
including verification of the material properties of the low pressure applied two component spray
polyurethane foam system on-site, the installation process, quality control measures, documentation of the
installation, limitations for the installation, site safety and disposal of associated waste.
1.4 This document is limited to installation in open cavities with framing members on each side of the
cavity and where the cavity can be visually inspected before and after the material is installed.
1.5 Injection into closed cavities is not permitted under the scope of this document.
1.6 This document does not purport to address all the health and safety aspects associated with the site
manufacture and installation of low pressure applied two component spray polyurethane foam. Anyone
using this document has the responsibility to consult the appropriate authorities and to establish
appropriate health and safety practices in conjunction with any existing applicable regulatory
requirements, prior to its use.
OEN:
ULC
Langue:
English
Code(s) de l'ICS:
91.120.10
Statut:
Norme
Date de Publication:
2021-04-11
Numéro Standard:
CAN/ULC-S743.2:2021