1 Scope
This part of IEC 61000 for EMC immunity requirements applies to electrical and electronic
equipment intended for use in residential, commercial, public and light-industrial locations.
Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to
be performed at frequencies where no requirements are specified.
This generic EMC immunity standard is applicable if no relevant dedicated product or productfamily
EMC immunity standard exists.
This standard applies to electrical and electronic equipment intended to be operated in
• residential locations, as defined in 3.8, both indoor and outdoor,
• commercial, public and light industrial locations, as defined in 3.9, both indoor and
outdoor.
This standard applies also to equipment which is battery operated or is powered by a nonpublic,
but non-industrial, low voltage power distribution system if this equipment is intended
to be used in the locations defined in 3.8 or 3.9.
This standard defines the immunity test requirements for equipment specified in the scope in
relation to continuous and transient, conducted and radiated disturbances, including
electrostatic discharges.
The immunity requirements have been selected to ensure an adequate level of immunity for
equipment operating within residential, commercial, public and light-industrial locations. The
levels do not, however, cover extreme cases, which may occur at any location, but with an
extremely low probability of occurrence. Not all disturbance phenomena have been included
for testing purposes in this standard, but only those considered as relevant for the equipment
covered by this standard. These test requirements represent essential electromagnetic
compatibility immunity requirements. They are specified for each port considered.
NOTE 1 Information on other disturbance phenomena is given in IEC TR 61000-4-1.
NOTE 2 Safety considerations are not covered by this standard.
NOTE 3 In special cases, situations will arise where the levels of disturbances may exceed the test levels
specified in this standard, for example where a hand-held transmitter is used in proximity to equipment. In these
instances, special mitigation measures may have to be employed.