CAN/CSA-C191-13
1.1 General
This Standard specifies requirements related to hot water delivery, minimum standby performance,
heater element ratings, and marking of electric storage tank water heaters.
1.2 Tank capacity
This Standard applies to stationary storage tank water heaters that have a rated capacity of 50 to 454 L
(11 to 100 gal) and are intended for use with pressure systems in residential premises and similar
locations. For convenience, the term “water heater” is used in this Standard to refer to such heaters.
1.3 Mandatory language
In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to
satisfy in order to comply with the standard; “should” is used to express a recommendation or that
which is advised but not required; and “may” is used to express an option or that which is permissible
within the limits of the standard. Notes accompanying clauses do not include requirements or alternative
requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or
informative material. Notes to tables and figures are considered part of the table or figure and may be
written as requirements. Legends to equations and figures are considered requirements.
1.4 Units of measurement
The values given in SI (metric) units are the standard. The values given in parentheses are for information
only. All measurements in gallons refer to imperial gallons.