C22.2 No. 1691-12 (R2016)
1 Scope
1.1 These requirements cover single pole locking-type separable attachment plugs, cord connectors,
panel inlets, and panel outlets, adapters, and accessories, rated up to a maximum of 800 amperes and
up to 600 volts ac or dc and not intended for connection or disconnection under load conditions.
1.2 These devices are intended to provide power from feeders or branch circuits, or are for direct
connection to feeders or branch circuits in accordance with the Canadian Electrical Code (CEC), Part I,
C22.1, and the National Electrical Code (NEC), ANSI/NFPA-70 for the following applications:
CEC
Amusement parks, midways, carnivals, film and TV sets, TV remote broadcasting locations, traveling
shows (Section 66) and similar venues and installations where such temporary connections could be
used.
NEC
a) Places of assembly (assembly occupancies) (Article 518)
b) Theaters, audience areas of motion picture and television studios, performance areas, and
similar locations (Article 520)
c) Carnivals, circuses, fairs and similar events (Article 525)
d) Motion pictures and television studios and similar locations (Article 530)
e) Motion picture projection rooms (Article 540)
f) Temporary installations such as construction sites (Article 590)
1.3 These devices are not intended for use in hazardous locations.
1.4 Attachment plugs and cord connectors are intended for use with cables, as defined in applicable
electrical codes, having copper conductors only, for use in either outdoor or indoor locations.
1.5 Inlets and outlets are intended for use with cables or bus bars, as defined in applicable electrical
codes, having copper conductors only, for use in either outdoor or indoor locations.
1.6 This Standard does not apply to:
a) Plugs, Receptacles, and Cable Connectors, of the Pin and Sleeve Type covered by UL 1682
and CSA C22.2 No. 182.1.
b) Devices molded integrally with flexible cord or cable that are covered by the Standard for
Cord Sets and Power-Supply Cords, UL 817, and Cord Sets and Power Supply Cords, CSA
C22.2 No. 21.
c) General and special use devices, such as attachment plugs, receptacles, cord connectors,
inlets, current taps, flatiron and appliance plugs, that are covered by the Standard for
Attachment Plugs and Receptacles, UL 498, and General Use Receptacles, Attachment Plugs,
and Similar Wiring Devices, CSA C22.2 No. 42, Appliance Plugs for Heater Cord Sets, CSA
C22.2 No. 57, and Industrial Locking Types, Special Use Attachment Plugs, Receptacles and
Connectors, CSA C22.2 No. 182.2.
d) Single and multi-pole connectors, which may include 3 or more pilot contacts, intended for
connection to copper conductors, for use in data, signal, control and power applications within
and between electrical equipment, where exposed, that are covered by the Standard for
Component Connectors for Use in Data, Signal, Control and Power Applications, UL 1977, and
Special Use Attachment Plugs, Receptacles and Connectors, CSA C22.2 No. 182.3.
e) Devices intended for use in hazardous (Classified) locations that are covered by the
Standard for Receptacle-Plug Combinations for Use in Hazardous (Classified) Locations, UL
1010, and Attachment Plugs, Receptacles and Similar Wiring Devices for Use in Hazardous
Locations: Class I, A, B, C, and D, Class II, Group G in Coal or Coke Dust, and in Gaseous
Mines, CSA C22.2 No. 159.
f) Products such as switched interlocks that are covered by the Standard for Industrial Control
Equipment, UL 508, and Industrial Control Equipment, CSA C22.2 No. 14.
g) Bus bar clamps covered by the Standard for Portable Power-Distribution Equipment, UL
1640.
h) Portable power distribution units covered by the Standard for Portable Power-Distribution
Equipment, UL 1640.