M421-11
1 Scope
1.1 Purpose
This Standard establishes minimum requirements for electrical work and electrical equipment operating,
or intended to operate, in mines.
Note: Users should be aware that federal, provincial, and territorial legislation can impose additional requirements.
1.2 Application
This Standard is intended to be used with the requirements of the Canadian Electrical Code, Part I, or local
regulatory amendment thereto, unless such requirements are modified by this Standard.
Note: Adherence to the Canadian Electrical Code, Part I, normally addresses the minimum electrical safety requirements
for mining-related fixed buildings, structures, and premises located on the surface, as these are no different from other
industrial facilities. Such facilities could include processing plants, camps, offices, and drys. However, specific applications can
exist within or on such buildings, structures, or premises that warrant the application of this Standard, e.g., the following
equipment operating at voltages exceeding 150 V to ground:
(a) mobile equipment fed by portable power cables;
(b) movable equipment fed by portable power cables where the ground-fault voltage and ground potential rise relative to
the surrounding earth or structures cannot be limited to 100 V; and
(c) quick-connect couplers that are not mechanically interlocked with a load-break-rated disconnect switch.
1.3 Application to non-mining structures
This Standard does not apply to tunnels, aqueducts, conduits, or excavations for civil construction
purposes. However, where mines incorporate such structures, this Standard applies.
1.4 Clause numbering system
This Standard is divided into seven clauses, numbered from 1 to 7. Clauses are further divided into
subclauses (e.g., Clause 4.3). There can be up to five levels of subclauses (e.g., Clause 4.3.3.3.1).
Multiple items, designated by lowercase letters in parentheses (e.g., (a), (b), (c)) can be enumerated in
a list. If an item requires further listing, subsidiary items are identified by lowercase Roman numerals in
parentheses (e.g., (i), (ii), (iii)). Items in a further list under these subsidiary items are identified by an
Arabic numeral in parentheses (e.g., (1), (2), (3)).
Note: For further information see CSA-SDP-3.2.
1.5 Inclusive lists and selective lists
The use of the conjunction “and” between two or more items in a sentence or list conveys an inclusive
relationship, i.e., all of the items or conditions in the list are included in the criteria (i.e., all items present or
conditions satisfied). The use of the conjunction “or” between two or more items in a sentence or list
conveys a selective relationship, i.e., at least one of the items or conditions in the list is included in the
criteria (i.e., a selective choice).
1.6 Terminology
In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the user is obliged to
satisfy in order to comply with the standard; “should” is used to express a recommendation or that which
is advised but not required; and “may” is used to express an option or that which is permissible within the
limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a
note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as
requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their
application.
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
29.260.20;
73.100.01
Statut:
Annulée
Date de Publication:
2011-03-31
Numéro Standard:
M421-11