CAN/CSA-B64 Series-07

Backflow Preventers and Vacuum Breakers
B64.0-07 1 Scope 1.1 The CSA B64 Series of Standards covers vacuum breakers and backflow preventers that are used in potable water supply systems to prevent cross-connections. 1.2 This Standard specifies definitions, general requirements, test methods, markings, and instructions that are common to some or all of the CSA B64 Series. 1.3 This Standard is not a complete Standard in itself and is intended to be used in conjunction with one of the Standards in the CSA B64 Series to form a complete Standard for a particular type of vacuum breaker or backflow preventer. 1.4 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 This Standard is written in SI (metric) units; for conversion tables, see Annex A. Vacuum is expressed in pressure below ambient. All pipe sizes are shown as nominal pipe sizes (NPS). --------------------------------------------------------------- B64.1.1-07 1 Scope This Standard covers atmospheric vacuum breakers (AVB). --------------------------------------------------------------- B64.1.2-07 1 Scope This Standard covers pressure vacuum breakers (PVB). --------------------------------------------------------------- B64.1.3-07 1 Scope This Standard covers spill-resistant pressure vacuum breakers (SRPVB). --------------------------------------------------------------- B64.2-07 1 Scope 1.1 This Standard covers hose connection vacuum breakers (HCVB). 1.2 CSA B64.2.1 and CSA B64.2.1.1 cover HCVB and HCDVB devices, respectively, that incorporate a manual draining feature, while CSA B64.2.2 covers HCVB devices that incorporate an automatic draining feature. --------------------------------------------------------------- B64.2.1-07 1 Scope This Standard covers hose connection vacuum breakers (HCVB) that incorporate a draining feature that requires manual operation. --------------------------------------------------------------- B64.2.1.1-07 1 Scope This Standard covers hose connection vacuum breakers that have two check valves (HCDVB) and that incorporate a draining feature that requires manual operation. The second (downstream) check valve is field-testable. --------------------------------------------------------------- B64.2.2-07 1 Scope This Standard covers hose connection vacuum breakers (HCVB) that incorporate an automatic draining feature that does not require manual operation. --------------------------------------------------------------- B64.3-07 1 Scope This Standard covers dual check valve backflow preventers with an atmospheric port (DCAP). --------------------------------------------------------------- B64.3.1-07 1 Scope This Standard covers dual check valve backflow preventers with an atmospheric port for carbonators (DCAPC). --------------------------------------------------------------- B64.4-07 1 Scope This Standard covers reduced pressure principle (RP) backflow preventers. --------------------------------------------------------------- B64.4.1-07 1 Scope This Standard covers reduced pressure principle backflow preventers specifically designed for use in fire protection systems (RPF). --------------------------------------------------------------- B64.5-07 1 Scope This Standard covers double check valve (DCVA) backflow preventers. --------------------------------------------------------------- B64.5.1-07 1 Scope This Standard covers double check valve backflow preventers specifically designed for use in fire protection systems (DCVAF). --------------------------------------------------------------- B64.6-07 1 Scope This Standard covers dual check valve (DuC) backflow preventers. --------------------------------------------------------------- B64.6.1-07 1 Scope This Standard covers dual check valve backflow preventers designed for use in fire protection systems (DuCF). --------------------------------------------------------------- B64.7-07 1 Scope 1.1 This Standard covers vacuum breakers for use on laboratory faucets. 1.2 Laboratory faucet vacuum breakers (LFVB) covered by this Standard are intended to be installed on the discharge side of the last control valve and are not intended for use under constant pressure conditions. --------------------------------------------------------------- B64.8-07 1 Scope This Standard covers dual check valve backflow preventers with an intermediate vent (DuCV). Note: These devices are designed to be used on individual outlets or appliances with flow rates of 0.25 L/s or less. --------------------------------------------------------------- B64.9-07 1 Scope This Standard covers single check valve backflow preventers specifically designed for use in fire protection systems (SCVAF).
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
23.060; 23.160
Statut:
Annulée
Date de Publication:
2007-06-30
Numéro Standard:
CAN/CSA-B64 Series-07