CAN/CSA-ISO/IEC 18012-1:05 (R2010)
1 Scope
This part of ISO/IEC 18012 specifies requirements for product interoperability in the area of
home and building automation systems. It specifies layers six and seven of the OSI reference
model (see ISO/IEC 7498-1) with sufficient detail needed to design interoperable home
electronic system products, while layers one to five are only specified to the point needed to
check whether devices will be able to interoperate with one another.
ISO/IEC 18012-1 is applicable to
• stand-alone local/home networks, connected devices and applications,
• mixed local/home networks, connected devices and applications,
• automatically configured devices,
• installer configured devices,
• installer configured groups/clusters of devices.
ISO/IEC 18012-1 specifies interoperability for system set-up, operation and management
applied to devices connected to a single home control system or to different home control
systems. Although a single uniform home control system would simplify operations, this
standard recognises that multiple different networks may co-exist in the same house. This
standard specifies requirements to assure that devices from multiple manufacturers work
together to provide a specific application. Also, a specific device could be used for multiple
applications.
ISO/IEC 18012-1 specifies interoperability requirements with respect to
• safety,
• addressing,
• applications,
• transport of information,
• set-up of devices/elements within home networks – static and/or dynamic binding between
objects,
• management.
This document does not specify how two home control systems share a common resource or
how to ensure that two home control systems used within the same premises do not interfere
with each other. However, this document requires that two home control systems may share a
common resource, and that they do not interfere with one another.
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
35.240.99;
35.200
Statut:
Norme
Date de Publication:
2005-09-30
Numéro Standard:
CAN/CSA-ISO/IEC 18012-1:05 (R2010)