CAN/CSA-Z9170-1-00 (R2010)
International Standard ISO 9170-1:1999 has been adopted with Canadian
deviations as CSA Standard CAN/CSA-Z9170-1-00.
1 Scope
This part of ISO 9170 specifies requirements for terminal units intended for
use in medical gas pipeline systems in accordance with ISO 7396-1, for use with
the following services:
- oxygen;
- nitrous oxide;
- air for breathing;
- carbon dioxide;
- oxygen/nitrous oxide mixture [50 %/50 % (by volume)];
- air for driving surgical tools;
- nitrogen for driving surgical tools;
- vacuum.
It is intended especially to ensure the gas-specific assembly of terminal units
and to prevent their interchange between different gases.
This part of ISO 9170 specifies requirements for terminal units for supply and
disposal of nitrogen or air for driving surgical tools.
This part of ISO 9170 specifies requirements for probes intended to be
connected to the gas-specific connection point which is part of the terminal
unit.
This part of ISO 9170 does not specify the dimensions of probes and of the
gas-specific connection points of the terminal units.
This part of ISO 9170 does not specify the dimensions of NIST connectors, which
are defined in ISO 5359.
This part of ISO 9170 does not specify the requirements for terminal units for
anaesthetic gas scavenging systems (AGSS), which are defined in ISO 9170-2.
NOTE 1 The requirements of this part of ISO 9170 may be used as guidelines
for terminal units for other medical gases. These medical gases will be
considered for inclusion in this part of ISO 9170 when they come into general
use.
NOTE 2 Throughout this part of ISO 9170, clauses for which a rationale is
provided in annex A are indicated by a boldface capital R.
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
11.040.10
Statut:
Annulée
Date de Publication:
2000-05-31
Numéro Standard:
CAN/CSA-Z9170-1-00 (R2010)