ULC-S635-00

Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents
1. SCOPe 1.1 This Standard covers lining systems for existing masonry chimneys, which may or may not incorporate a liner of fire-clay tile, or factory-built chimneys and vents. 1.2 Lining systems shall be classed as follows: Class 1 -- For the venting of gas-fired appliances where the temperature of the flue-gas products is 135°C or above, but does not exceed 245°C; Class 2 -- For the venting of oil and gas-fired appliances where the temperature of the flue-gas products does not normally exceed 300°C; and Class 3 -- For the venting of oil-, gas- and solid fuel-fired appliances where the temperature of the flue-gas products does not normally exceed 650°C. 1.3 Lining systems as covered by these requirements, are not intended for use with Type BH Gas Vents, or with appliances that create positive pressures within the lining system, or cause condensation of corrosive acids.
OEN:
ULC
Langue:
English
Code(s) de l'ICS:
91.060.40
Statut:
Annulée
Date de Publication:
2000-06-29
Numéro Standard:
ULC-S635-00