CAN/CSA-C828-99 (R2005)
1. Scope
1.1
This Standard provides requirements for thermostat models intended to be used
for line-voltage (120-240 V) switching of a controlled resistive heating load
that may include a fan, if so specified or provided for by the thermostat
manufacturer. It includes single- and double-pole thermostats controlling
their load either by fast or slow ON/OFF switching. These models may be one of
the following types:
(a) line-voltage wall-mounted;
(b) line-voltage built-in (up to 1500 W); or
(c) line-voltage two-component thermostats.
1.2
This Standard provides performance requirements regarding thermal regulation
and power line quality. The thermal regulation requirements are defined for a
dual-climate room test set-up. The power line quality requirements specify the
level of emissions that may be generated by the line-voltage thermostats and
their level of susceptibility to electromagnetic disturbances that may be
present on the power line.
1.3
This Standard provides requirements only for local zone thermostats; it does
not apply to central heating units under the control of a single thermostat.