B137.9-98
1. Scope
1.1
The Standard sets out requirements for macrocomposite pipes consisting of a
welded aluminum tube laminated by a melt adhesive to layers of polyethylene
inside and outside the aluminum tube. The Standard also provides requirements
for fittings (connectors) for use with this composite pipe. The pipes
considered in this Standard are for use in potable water supply systems and are
pressure rated for 1380 kPa (200 psi) at 23°C and/or 1035 kPa (150 psi) at
60°C.
1.2
The Standard includes requirements for materials, quality of work, dimensions,
thermocycling resistance, sustained pressure performance, delamination
resistance, and marking.
Notes:
(1) In developing the hydrostatic design basis for the pipes, in accordance
with CSA Standard B137.0, the fibre stress has been replaced by pressure.
(2) The pressure rating of macrocomposite pipes is sensitive to the thickness
of the aluminum metal reinforcing layer. Pipes having the same dimension
ratio but different metal reinforcing layer thicknesses will have different
pressure ratings. Dimension ratio therefore cannot be used, as with
homogeneous walled pipes, for assessing changes in pressure rating with wall
thickness variation.
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
23.040.01;
23.040.90;
77.150.10
Statut:
Annulée
Date de Publication:
1998-01-30
Numéro Standard:
B137.9-98