ULC-S636-95

Standard for Type BH Gas Venting Systems
1. SCOPe 1.1 These requirements cover the design, construction, and performance of gas venting systems intended for negative or positive pressure venting of gas-fired appliances producing flue gases having temperatures as specified in Clauses 1.2 and 1.3. 1.2 Class I venting systems are suitable for gas-fired appliances producing flue gas temperatures of more than 135°C but not more than 245°C. 1.3 Class II venting systems are suitable for gas-fired appliances producing flue gas temperatures of 135°C or less. 1.4 Class II venting systems are further classified into four temperature ratings as follows: A Up to and including 65°C; B Up to and including 90°C; C Up to and including 110°C; and D Up to and including 135°C.