CAN/CSA-B137.10-M91
1. Scope
1.1
The Standard covers macrocomposite pipes consisting of a welded aluminum tube
laminated by a melt adhesive to layers of crosslinked
polyethylene inside and outside the aluminum tube. The Standard
also covers fittings (connectors) for use with this composite
pipe. The pipes covered in this Standard are for use in potable
cold and hot water supply, central heating, and underfloor
heating systems, and are pressure rated for 1380 kPa (200 psi) at
23°C and/or 860 kPa (125 psi) at 82°C.
1.2
The Standard includes requirements for materials, workmanship, dimensions,
thermocycling resistance, sustained pressure performance, delamination
resistance, and marking.
Notes:
(1) In developing the hydrostatic design basis for the pipes, in accordance
with CSA Standard CAN3-B137.0, the fibre stress has been replaced by pressure.
(2) The pressure rating of macrocomposite pipes is sensitive to the thickness
of the aluminum metal reinforcing layer. Pipes having the same dimension ratio
but different metal reinforcing layer thicknesses will have different pressure
ratings. Dimension ratio cannot therefore be used, as with homogeneous walled
pipes, for assessing changes in pressure rating with wall thickness variation.
OEN:
CSA
Langue:
English
Code(s) de l'ICS:
23.040.20;
23.040.01
Statut:
Annulée
Date de Publication:
1991-04-29
Numéro Standard:
CAN/CSA-B137.10-M91