Polypropylene (PP-R and PP-RCT) pipe and fittings for pressure applications
1 Scope
1.1 General
This Standard covers two types of polypropylene (PP) pipe and fittings – polypropylene random copolymer (PP-R) and polypropylene random copolymer with modified crystallinity and temperature resistance (PP-RCT) intended for use in pressure applications such as hot and cold potable water distribution systems, process piping, reclaimed/recycled water systems, water service,…
1 Scope
1.1 General
This Standard covers polyamide (PA) pipe, tubing, and fittings for use in gas mains and services, including the gathering, transmission, and distribution of gases that can contain aromatic hydrocarbons.
1.2 Fittings and connections
This Standard covers all types of fittings and connections used in PA piping systems for gas services, including plastic-to-metal transition…
Polyethylene of raised temperature resistance (PE-RT) tubing systems for pressure applications
1 Scope
1.1 General
This Standard specifies requirements for polyethylene of raised temperature (PE-RT) tubing systems that comprise tubing, with or without a barrier layer, and fittings.
Tubing covered by this Standard is made in SDR 9.
Systems are pressure rated at two temperatures: 1105 kPa at 23 °C and 690 kPa at 82 °C. Systems are intended for use in potable water distribution systems or…
Crosslinked polyethylene (PEX) piping systems for gas services
1 Scope
1.1 General
This Standard covers crosslinked polyethylene (PEX) pipe and fittings for use in gas mains and services, including gas gathering, gas transmission, and distribution of fuel gases.
1.2 Pipe
This Standard covers PEX pipes in metric nominal sizes DN 16 to DN 1000 or nominal pipe sizes NPS-3 to NPS-54 that are
a)
pressure-rated using the hydrostatic design basis (HDB) rating…
Medical electrical equipment — Part 2-1: Particular requirements for the basic safety and essential ...
Scope
Replacement:
This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTRON
ACCELERATORS, hereafter referred to as ME EQUIPMENT, in the range 1 MeV to 50 MeV, used for
TREATMENT of PATIENTS.
NOTE 1 While ELECTRON ACCELERATORS used for TREATMENT of PATIENTS are always ME EQUIPMENT, there are times
in this document where they are referred to as EXTERNAL BEAM…
Medical electrical equipment — Part 2-20: Particular requirements for the basic safety and essential...
Scope
Replacement:
This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT
TRANSPORT INCUBATOR equipment, as defined in 201.3.208, also referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the…
Medical electrical equipment — Part 2-21: Particular requirements for the basic safety and essential...
Scope
Replacement:
This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT
RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the
case, the clause…
Medical electrical equipment — Part 2-22: Particular requirements for basic safety and essential per...
Scope
Replacement:
This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of laser
equipment for surgical, therapeutic, medical diagnostic, cosmetic or veterinary applications,
intended for use on humans or animals, classified as LASER PRODUCT of CLASS 1C where the
ENCLOSED LASER is of CLASS 3B or 4, or CLASS 3B, or CLASS 4.
MEDICAL ELECTRICAL EQUIPMENT or MEDICAL…
Medical electrical equipment — Part 2-33: Particular requirements for the basic safety and essential...
Scope
Replacement:
This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MAGNETIC
RESONANCE (MR) EQUIPMENT and MAGNETIC RESONANCE (MR) SYSTEMS.
NOTE Where ME EQUIPMENT and ME SYSTEMS are used in the clause headings, this is to be understood to indicate
MR EQUIPMENT and MR SYSTEMS.
This document does not cover the application of MR EQUIPMENT beyond the INTENDED USE.
If a…
Medical electrical equipment — Part 2-41: Particular requirements for the basic safety and essential...
Scope
Replacement:
This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of SURGICAL
LUMINAIRES and LUMINAIRES FOR DIAGNOSIS, hereafter referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the
case, the…