Traditional Chinese Medicine — Polygonum multiflorum root
This document specifies the quality and safety requirements and test methods of Polygonum multiflorum root, which is derived from the root of Polygonum multiflorum Thunb. (Fam. Polygonaceae).
This document is applicable to Polygonum multiflorum root that are sold and used as natural medicines in international trade, including Chinese Materia Medica (whole medicinal material) and decoction pieces…
Meteorology — Radiosonde — Part 1: Laboratory test method for calibration error of temperature senso...
This International Standard proposal specifies technical requirements and test method for temperature sensor in radiosonde. This International Standard is applicable to the temperature measurement traceable to SI unit in boom sensors according to variations of pressure and air speed under the simulated conditions of upper air.
This proposed standard will mainly provide
a) Terms and definitions…
Natural gas — Calculation of methane number of gaseous fuels for reciprocating internal combustion e...
Part 2 of ISO 17507 describes the calculation method for the methane number of a gaseous fuel according to the methodology developed by DNV in a consortium with leading engine OEMs and fuel gas suppliers.
Natural gas — Calculation of methane number of gaseous fuels for reciprocating internal combustion e...
Part 1 of ISO 17507 describes the calculation method for the methane number of a gaseous fuel according to the methodology first proposed Deutz (“Klöckner-Humboldt-Deutz AG”) and later amended by MWM (“Motoren-Werke Mannheim AG”).
Aciers et fontes — Détermination du carbone total — Méthode par absorption dans l'infrarouge ap...
La présente Norme internationale prescrit une méthode de dosage du carbone total dans les aciers et les fontes par absorption dans l'infrarouge après combustion dans un four à induction. La méthode est applicable aux teneurs en carbone comprises entre 0,003 % (m/m) et 4,5 % (m/m).
Road vehicles — Field load specification for brake actuation and modulation systems
This document specifies expected field loads for functions provided by the braking system actuator and modulator and applies to passenger cars and light commercial vehicles (classes M1 and N1, according to UNECE).
Functions addressed in this document are:
— dynamic stability functions (e.g. electronic stability control);
— brake torque optimizing functions (e.g. electronic brake force…
Air cargo unit load devices — Performance requirements and test parameters
This document specifies the minimum requirements for airworthiness approval of air cargo pallets, nets and containers, generally designated as air cargo unit load devices (ULD).
This document is intended to provide a uniform technical reference for air cargo unit load devices approval. As a prerequisite, it is presupposed that the applicable general civil aviation requirements and the aircraft…
Information security, cybersecurity and privacy protection — Security and privacy requirements for a...
This document provides high level security and privacy requirements for authentication using biometrics on mobile devices, including security and privacy requirements for functional components, for communication, for storage and for remote processing.
This document is applicable to remote modes, i.e., the cases that:
- the biometric sample is captured through mobile devices;
- the biometric…
Environmental solid matrices — Determination of elements using inductively coupled plasma mass spect...
This document specifies a method for the determination of the following elements in aqua regia, nitric acid or mixture of hydrochloric (HCl), nitric (HNO3) and tetrafluoroboric (HBF4)/hydrofluoric (HF) acid digests of soil, treated biowaste, waste, sludge and sediment using inductively coupled plasma mass spectrometry (ICP-MS):
Aluminium (Al), antimony (Sb), arsenic (As), barium (Ba), beryllium (…
Radiological protection — Medical proton accelerators — Requirements and recommendations for shieldi...
This International Standard is applicable to radiation shielding design and evaluation work for medical proton accelerators with nominal energies of the beam ranging from 70 MeV to 250 MeV, with subsystem such as beamlines, energy selection system (for cyclotron) and nozzle components.
The radiation protection requirements and recommendations given in this international standard cover the…