1. Scope
1.1 General
1.1.1 This Standard specifies minimum requirements for a supplier's Quality Assurance Program - Category 3. The supplier is responsible for planning and developing a program aimed primarily at controlling inspection and test verifications which (a) assure that products or services conform to specified requirements; and (b) readily detect and control the…
1. Scope
1.1 General
1.1.1 This Standard specifies minimum requirements for a supplier's quality assurance program - Category 4. The supplier is responsible for planning and developing a program which provides objective evidence that contract requirements are met and which detects and dispositions nonconforming products or services.
1.1.2 This Standard may be applied to…
Asphalt Shingle Application on Roof Slopes 1:6 to Less Than 1:3
1. Scope
1.1
This Standard describes the minimum application requirements for asphalt strip shingles or low slope shingles on roofs with slopes from 1:6 to less than 1:3.
Note: Roof Substrate and Ventilation Below Substrate. Appendix A is included to provide recommendations for acceptable substrate for shingles; Appendix B, recommendations for acceptable ventilation below the shingle…
Asphalt Shingle Application on Roof Slopes 1:3 and Steeper
1. Scope
1.1
This Standard describes the minimum application requirements for asphalt strip shingles on roofs with slopes 1:3 and steeper.
Note: Roof Substrate and Ventilation Below Substrate. Appendix A is included to provide recommendations for acceptable substrate for shingles; Appendix B, recommendations for a cceptable ventilation below the shingle substrate; and Appendix C,…
1. Scope
1.1 This Standard applies to thermal cut-offs (TCO) for voltages up to and including 600 V, intended for the protection of equipment such as electric motors, transformers, fluorescent lighting ballasts, and electric heating appliances to be used indoors in accordance with the Rules of the Canadian Electrical Code, Part I. Notes: (1) Thermal cut-offs function once only and are used for…
Divides non-assembled strips into three quality grades that are identified by (+++), (++), (+) corresponding to the conditions specified in the tables. Designation or names for these quality grades may be assigned in national standards, provided that such standard indicate, at least in a note, the relationship with the ISO classification. Replaces Recommendation ISO/R 1324-1970 of which it…
High Efficiency Air-Cleaning Assemblies for Normal Operation of Nuclear
Facilities
1. Scope
1.1 General This Standard covers once-through high efficiency air-cleaning assemblies for maintaining radioactive particulate and radioiodine releases below licenced limits in nuclear power plants. The Standard identifies and establishes minimum requirements for the design, manufacture, installation, and preoperational acceptance testing for any or all of the following components…
Rubber, vulcanized — Determination of tension fatigue
Describes a method relating to fatigue under repeated deformations. Believed to be suitable for reasonably stable stress-strain properties. Materials to be tested must meet special criteria, otherwise experiment and interpretation may be difficult. Distinction should be made between this test and the flexometer tests of ISO 4666/1 to 3. Caution when relating standard test results to service…
1. Scope
1.1 This Standard covers the details of construction, performance, and test for portable and stationary electrical instruments for sensing the presence of combustible gas or vapour concentrations in air, parts of which may be installed or us ed in Class I hazardous locations and gaseous mines in accordance with the Rules of the Canadian Electrical Codes, Parts I and V.
1.2…
Construction and Test of Electric Cranes and Hoists
1. Scope
1.1 This Standard applies to all types of electric cranes, hoists, and monorails for voltages of 750 V and less between conductors, designed to be installed and used in accordance with the Rules of the Canadian Electrical Code, Part I.
1.2 This Standard includes the design of the collector arrangements for the contact conductors along the main runway.
Note: The…