1. Scope
1.1 This Standard applies to thermal cut-offs (TCO) for voltages up to and including 600 V, intended for the protection of equipment such as electric motors, transformers, fluorescent lighting ballasts, and electric heating appliances to be used indoors in accordance with the Rules of the Canadian Electrical Code, Part I. Notes: (1) Thermal cut-offs function once only and are used for…
Divides non-assembled strips into three quality grades that are identified by (+++), (++), (+) corresponding to the conditions specified in the tables. Designation or names for these quality grades may be assigned in national standards, provided that such standard indicate, at least in a note, the relationship with the ISO classification. Replaces Recommendation ISO/R 1324-1970 of which it…
High Efficiency Air-Cleaning Assemblies for Normal Operation of Nuclear
Facilities
1. Scope
1.1 General This Standard covers once-through high efficiency air-cleaning assemblies for maintaining radioactive particulate and radioiodine releases below licenced limits in nuclear power plants. The Standard identifies and establishes minimum requirements for the design, manufacture, installation, and preoperational acceptance testing for any or all of the following components…
Rubber, vulcanized — Determination of tension fatigue
Describes a method relating to fatigue under repeated deformations. Believed to be suitable for reasonably stable stress-strain properties. Materials to be tested must meet special criteria, otherwise experiment and interpretation may be difficult. Distinction should be made between this test and the flexometer tests of ISO 4666/1 to 3. Caution when relating standard test results to service…
1. Scope
1.1 This Standard covers the details of construction, performance, and test for portable and stationary electrical instruments for sensing the presence of combustible gas or vapour concentrations in air, parts of which may be installed or us ed in Class I hazardous locations and gaseous mines in accordance with the Rules of the Canadian Electrical Codes, Parts I and V.
1.2…
Construction and Test of Electric Cranes and Hoists
1. Scope
1.1 This Standard applies to all types of electric cranes, hoists, and monorails for voltages of 750 V and less between conductors, designed to be installed and used in accordance with the Rules of the Canadian Electrical Code, Part I.
1.2 This Standard includes the design of the collector arrangements for the contact conductors along the main runway.
Note: The…
Cinematography — Underexposed motion-picture film requiring forced development — Designation method
1 .1 This International Standard specifies a method of designating underexposed motion-picture negative and reversal type film requiring forced or push-processing development.
1.2 This International Standard does not specify the procedure used in achieving a forced development result.
NOTE - An International Standard dealing with overexposed motionpicture film is being prepared.
1. Scope
1.1 This Standard applies to rigid unplasticized poly(vinyl chloride) conduit, elbows, bends, and couplings intended for use at a continuous operating temperature of 75°C for the installation of wires and cables in accordance with the Rules of the Canadian Electrical Code, Part I, for nonhazardous locations. Note: See Canadian Electrical Code, Rule 12-1204.
1.2 The products…
1. Scope
1.1 This Standard applies to nonmetallic conduit of rigid PVC, type EB1 for encasement in concrete or masonry and type DB2/ES2 for direct burial or encasement in concrete or masonry, and their associated fittings, in accordance with the Rules of the Canadian Electrical Code, Part I, for ordinary locations.
1.2 The conduits and associated fittings covered by this Standard are…
Cables and Cable Glands for Use in Hazardous Locations
1. Scope
1.1 This Standard applies to cables and cable glands intended for
(a) fixed wiring in Class I, Groups A, B, C, and D; Class II, Groups E, F, and G; and Class III hazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I; and
(b) fixed wiring and portable cables in gaseous mines in accordance with the Rules of the Canadian Electrical Code, Part V; and…