Basic and safety principles for man-machine interface, marking and identification — Coding principle...
1 Scope
This International Standard establishes general rules for assigning particular meanings to
certain visual, acoustic and tactile indications in order to
– increase the safety of persons, property and/or the environment through the safe
monitoring and control of the equipment or process;
– facilitate the proper monitoring, control and maintenance of the equipment or process;
– facilitate…
1 Scope
1.1
The purpose of this Standard is to specify pool pump performance measurements that will facilitate the
selection of the most efficient models for performing the combined functions of filtration and pool cleaning.
1.2
This Standard applies to energy performance of centrifugal pump units for the purpose of circulating and
filtering water in residential permanently installed…
1 Scope
1.1 General
This Standard specifies design, testing, marking, and information requirements for use of full body
harnesses. Full body harnesses are intended for use as body supports in personal fall arrest systems and in
other work situations that involve the risk of falling.
1.2 Exclusions
This Standard does not cover full body harnesses for use in recreational situations such…
Audio/video, information and communication technology equipment — Part 1: Safety requirements
1 Scope
This part of IEC 62368 is applicable to the safety of electrical and electronic equipment within the field of
audio, video, information and communication technology, and business and office machines with a rated
voltage not exceeding 600 V. This standard does not include requirements for performance or functional
characteristics of equipment.
NOTE 1 Examples of equipment within…
Competency Standard for diving, hyperbaric chamber, and remotely operated vehicle operations
1 Scope
1.1
This Standard applies to occupational diving, hyperbaric facility, and remotely operated vehicle (ROV)
operations conducted in connection with all types of work and employment and describes the
requirements for minimum competency levels for all personnel directly associated with the identified
techniques of diving or ROV operations.
Canadian safety and health legislation…
1 Scope
This Standard specifies requirements for profile steel reinforced polyethylene (SRPE) sewer pipe and fittings for storm sewer, and other gravity-flow applications.
Profile wall pipe in this Standard includes open profile pipe of helical construction, with a smooth interior and sizes based on controlled inside diameter. The pipe can be perforated, for specific applications, as required.…
Medical electrical equipment — Part 2-46: Particular requirements for the basic safety and essential...
This particular standard specifies safety requirements for OPERATING TABLES, whether or not
having electrical parts, including TRANSPORTERS, used for the transportation of the table top to
or from the base or pedestal of an OPERATING TABLE with detachable table top.
NOTE See also 4.2 of the General Standard.
This particular standard does not apply to
– dental patient chairs;
–…
Medical electrical equipment — Part 2-8: Particular requirements for the basic safety and essential ...
This international standard applies to the basic safety and essential performance of
therapeutic X-RAY EQUIPMENT with NOMINAL X-RAY TUBE VOLTAGES in the range 10 kV to 1 MV
when connected to alternating current SUPPLY MAINS, hereafter referred to as ME EQUIPMENT.
NOTE This standard covers TELETHERAPY and BRACHYTHERAPY.
If a clause or subclause is specifically intended to be applicable to ME…
Medical electrical equipment — Part 2-4: Particular requirements for the basic safety and essential ...
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
CARDIAC DEFIBRILLATORS, hereafter referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME…
Medical electrical equipment — Part 2-28: Particular requirements forthe basic safety and essential ...
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of X-RAY
TUBE ASSEMBLIES and to components thereof:
– hereafter referred to as ME EQUIPMENT;
– intended for medical diagnosis and imaging.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will…