1 Scope
1.1
This Standard applies to newly produced non-metallic dip tubes intended for use in water heaters.
1.2
Compliance of a dip tube with this Standard does not imply that such dip tube is acceptable for use in
water heaters without supplemental tests with the dip tube installed in the particular water heater
design.
1.3
This standard contains SI (Metric) corresponding to the yard/pound…
Decommissioning of facilities containing nuclear substances
Scope
1.1
This Standard applies to the decommissioning of licensed facilities and other locations where nuclear substances are managed, possessed, or stored.
Notes:
(1) Users are responsible for determining the extent to which this Standard applies to a given facility or location and for
consulting the associated regulatory requirements.
(2) Annexes E, F, and G contain recommended…
1.1 General
This Standard specifies requirements for the structural design of unreinforced, reinforced, and
prefabricated masonry structures and components in accordance with the limit states design method of
the National Building Code of Canada. This Standard also provides requirements for the structural design of
prestressed masonry beams, walls, and columns in accordance with the limit…
Mechanical vibration — Evaluation of machine vibration by measurements on non-rotating parts — Part ...
ISO 10816-8:2014 establishes procedures and guidelines for the measurement and classification of mechanical vibration of reciprocating compressor systems. The vibration values are defined primarily to classify the vibration of the compressor system and to avoid fatigue problems with parts in the reciprocating compressor system, i.e. foundation, compressor, dampers, piping, and auxiliary equipment…
Scope
1.1
This Standard specifies test procedures to determine the performance of general service directional lamps.
Note: This Standard is intended to be technology neutral.
1.2
This Standard does not include requirements for luminaires used with general service lamps and for coloured directional lamps.
Notes:
1) For the purpose of this Standard, general service lamps refer to…
Scope
1.1
This Standard defines minimum energy efficiency and performance requirements for light emitting diode (LED) lamps with an ANSI or IEC standardized base that are designed to connect to a low-voltage or branch circuit via a lampholder. The criteria in this Standard apply to both integral LED lamps of nonstandard form, and to those intended to replace standard general service…
1.1
This Standard applies to indoor and outdoor meter-mounting devices, either as complete self-contained
devices or provided as a part of service equipment, for use in nonhazardous locations, and intended to
be employed in accordance with the Rules of the Canadian Electrical Code, Part I (“CEC Part I”).
1.2
This Standard covers devices for use with watt hour meters, demand meters, time…
1.1
This Standard applies to electric motors and generators for installation and use, in accordance with the
Rules of the Canadian Electrical Code, Part I, in non-hazardous locations.
Note: The term “machine” throughout this Standard should be assumed to mean “motor” and “generator”.
1.2
Clauses 2 to 7 are general in nature and apply, unless otherwise noted, to the motors and generators…
Operators and systems of doors, gates, draperies, and louvres
1.1
This Standard applies to electrically-powered door opening devices and other opening and closing
appliances rated at 600 V or less and intended to be used in nonhazardous locations in accordance with
the Rules of the Canadian Electrical Code, Part I.
1.2
This Standard gives requirements for complete doors, gates, and other such assemblies that include
electrically-powered opening and…
1.1
This Standard applies to single- and multiple-conductor fire alarm and signal cables with a maximum
nominal voltage rating of 300 V and a minimum temperature rating of 60 °C for use in buildings and
other structures in dry or damp locations in accordance with the Rules of Sections 16 and 32 of the
Canadian Electrical Code, Part I.
1.2
Because other CSA Group Standards specify…